PURPOSE: To evaluate the impact of higher-order aberrations on depth of focus using an adaptive optics visual simulator.SETTING: Refractive Surgery Department, Cole Eye Institute, Cleveland Clinic, Cleveland, Ohio, USA.METHODS: An adaptive optics simulator was used to optically introduce individual aberrations in eyes of subjects with a 6.0 mm pupil under cycloplegia (coma and trefoil, magnitudes +/- 0.3 mu m; spherical aberration, magnitudes +/- 0.3, +/- 0.6, +/- 0.9 mu m). A through-focus response curve was assessed by recording the percentage of Sloan letters at a fixed size identified at various target distances. the subject's ocular depth of focus and center of focus were computed as the half-maximum width and the midpoint of the through-focus response curve.RESULTS: the dominant eyes of 10 subjects were evaluated. the simulation of positive or negative spherical aberration had the effect of enhancing depth of focus and resulted in linearly shifting of the center of focus by 2.6 dicipters (D)/mu m of error. This increase in depth of focus reached a maximum of approximately 2.0 D with 0.6 mu m of spherical aberration and became smaller when the aberration was increased to 0.9 mu m. Trefoil and coma appeared to neither shift the center of focus nor significantly modify the depth of focus.CONCLUSION: the introduction of both positive and negative spherical aberration using adaptive optics technology significantly shifted and expanded the subject's overall depth of focus; simulating coma or trefoil did not produce such effects. J Cataract Refract Surg 2009; 35:1885-1892 (C) 2009 ASCRS and ESCRSCleveland Clin, Cole Eye Inst, Cleveland, OH 44106 USAImagine Eyes, Orsay, FranceUniversidade Federal de São Paulo, São Paulo, BrazilUniversidade Federal de São Paulo, São Paulo, BrazilWeb of SciencKeywords
This publication has 15 references indexed in Scilit:
- Changes in through-focus spatial visual performance with adaptive optics correction of monochromatic aberrationsVision Research, 2008
- Spherical Aberration and Depth of Focus in Eyes Implanted with Aspheric and Spherical Intraocular Lenses: A Prospective Randomized StudyOphthalmology, 2007
- Correcting Highly Aberrated Eyes Using Large-stroke Adaptive OpticsJournal of Refractive Surgery, 2007
- Effects of Zernike Wavefront Aberrations on Visual Acuity Measured Using Electromagnetic Adaptive Optics TechnologyJournal of Refractive Surgery, 2007
- Higher-order aberrations of age-related cataractJournal of Cataract & Refractive Surgery, 2007
- Evidence for Delayed Presbyopia after Photorefractive Keratectomy for MyopiaOphthalmology, 2006
- Higher-order aberrations of lenticular opacitiesJournal of Cataract & Refractive Surgery, 2004
- Age-related changes in corneal and ocular higher-order wavefront aberrationsAmerican Journal of Ophthalmology, 2004
- Visual Acuity and Contrast Sensitivity for Individual Sloan LettersVision Research, 1997
- Relative Letter and Position Difficulty on Visual Acuity Charts from the Early Treatment Diabetic Retinopathy StudyAmerican Journal of Ophthalmology, 1993