Abstract
Background-The use of embolic protection devices (EPD) may theoretically reduce the occurrence of cerebral embolic lesions during transcatheter aortic valve implantation. Available evidence from single studies is inconclusive. The aim of the present meta-analysis was to assess the safety and efficacy profile of current EPD. Methods and Results-Major medical databases were searched up to December 2017 for studies that evaluated patients undergoing transcatheter aortic valve implantation with or without EPD. End points of interest were 30-day mortality, 30-day stroke, the total number of new lesions, the ischemic volume per lesion, and the total volume of lesions. Eight studies involving 1285 patients were included. The EPD delivery success rate was reported in all studies and was achieved in 94.5% of patients. The use of EPD was not associated with significant differences in terms of 30-day mortality (odds ratio 0.43 [0.18-1.05], P=0.3) but it was associated with a lower rate of 30-day stroke (odds ratio 0.55 [0.31-0.98], P=0.04). No differences were detected with respect to the number of new lesions (standardized mean difference -0.19 [-0.71 to 0.34], P=0.49). The use of EPD was associated with a significantly smaller ischemic volume per lesion (standardized mean difference, -0.52 [-0.85 to -0.20], P=0.002) and smaller total volume of lesions (standardized mean difference, -0.23 [-0.42 to -0.03], P=0.02). Conclusions-The use of EPD is not associated with a reduced rate of mortality and new ischemic cerebral lesions. The use of EPD during transcatheter aortic valve implantation seems to be associated with a lower 30-day stroke rate, although this result is driven by a single nonrandomized study. The use of EPD is associated with a smaller volume of ischemic lesions, and smaller total volume of ischemic lesions.Keywords
This publication has 27 references indexed in Scilit:
- Updated Standardized Endpoint Definitions for Transcatheter Aortic Valve ImplantationJournal of the American College of Cardiology, 2012
- Cerebral Embolization During Transcatheter Aortic Valve ImplantationCirculation, 2012
- Diffusion-weighted MRI determined cerebral embolic infarction following transcatheter aortic valve implantation: assessment of predictive risk factors and the relationship to subsequent health statusHeart, 2011
- Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk PatientsNew England Journal of Medicine, 2011
- Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo SurgeryNew England Journal of Medicine, 2010
- Silent and Apparent Cerebral Ischemia After Percutaneous Transfemoral Aortic Valve ImplantationCirculation, 2010
- Cerebral Ischemic Lesions on Diffusion-Weighted Imaging Are Associated With Neurocognitive Decline After Cardiac SurgeryStroke, 2008
- Postcardiac Surgical Cognitive Impairment in the Aged Using Diffusion-Weighted Magnetic Resonance ImagingThe Annals of Thoracic Surgery, 2007
- Clinically Silent Cerebral Ischemic Events After Cardiac Surgery: Their Incidence, Regional Vascular Occurrence, and Procedural DependenceThe Annals of Thoracic Surgery, 2006
- Small ischemic brain lesions after cardiac valve replacement detected by diffusion-weighted magnetic resonance imaging: relation to neurocognitive function☆European Journal of Cardio-Thoracic Surgery, 2005