Submental Perforator Flap Design with a Near-Infrared Fluorescence Imaging System: The Relationship among Number of Perforators, Flap Perfusion, and Venous Drainage
Open Access
- 1 October 2009
- journal article
- research article
- Published by Ovid Technologies (Wolters Kluwer Health) in Plastic and Reconstructive Surgery
- Vol. 124 (4), 1098-1104
- https://doi.org/10.1097/prs.0b013e3181b5a44c
Abstract
Background: The submental flap is a reliable alternative to microsurgical reconstruction of facial deformities, providing an excellent cosmetic match with the contour and color of the face. In this study, the authors evaluated submental flap design by using near-infrared fluorescence angiography to identify perforator arteries. The impact of the number of preserved perforator arteries on flap perfusion and venous drainage was quantified. Methods: Indocyanine green was injected intravenously into 18 pigs. Three groups of six animals each had one, two, or three perforator arteries preserved. The fluorescence-assisted resection and exploration near-infrared fluorescence imaging system was used for image acquisition. Images were recorded before and after flap creation, and every hour, for 6 hours. The time to maximum perfusion, the drainage ratio (an indicator of venous drainage), and the percentage of perfused flap area were analyzed statistically at each time point. Results: Flaps with a single dominant perforator artery had an initial mean perfused area of 80 percent, which improved to 97 percent at 6 hours. For flaps with two and three preserved perforator arteries, perfused area at 6 hours was 99.8 percent and 100 percent, respectively. A significant increase was observed in all three metrics as more vessels were preserved. Regardless of the number of perforator arteries preserved, though, all three metrics improved over 6 hours. Conclusions: Near-infrared fluorescence angiography can reliably identify submental perforator arteries for flap design and can be used to assess flap perfusion and venous drainage in real time. Flap metrics at 6 hours were equivalent when either one or multiple perforator arteries were preserved.Keywords
This publication has 12 references indexed in Scilit:
- Quantitative Assessment of Perfusion and Vascular Compromise in Perforator Flaps Using a Near-Infrared Fluorescence-Guided Imaging SystemPlastic and Reconstructive Surgery, 2009
- High-Power, Computer-Controlled, Light-Emitting Diode–Based Light Sources for Fluorescence Imaging and Image-Guided SurgeryMolecular Imaging, 2009
- Real-Time Intraoperative Near-Infrared Fluorescence Angiography for Perforator Identification and Flap DesignPlastic and Reconstructive Surgery, 2009
- A theoretical model describing arterial flow in the DIEP flap related to number and size of perforator vesselsJournal of Plastic, Reconstructive & Aesthetic Surgery, 2008
- Submental perforator flap: Location and number of submental perforating vesselsScandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery, 2008
- Image-Guided Oncologic Surgery Using Invisible Light: Completed Pre-Clinical Development for Sentinel Lymph Node MappingAnnals of Surgical Oncology, 2006
- A 10-Year Retrospective Review of 758 DIEP Flaps for Breast ReconstructionPlastic and Reconstructive Surgery, 2004
- An Anatomic Study and Clinical Applications of the Reversed Submental Perforator-Based Island FlapPlastic and Reconstructive Surgery, 2002
- Near‐Infrared Images Using Continuous, Phase‐Modulated, and Pulsed Light with Quantitation of Blood and Blood OxygenationaAnnals of the New York Academy of Sciences, 1998
- Infrared Videoangiofluorography of the Skin with Indocyanine Green—Rat Random Cutaneous Flap Model and Results in ManMicrovascular Research, 1994