Abstract
In cardiac perfusion examinations with computed tomography (CT) large concentrations of iodine in the ventricle and in the descending aorta cause beam hardening artifacts that can lead to incorrect perfusion parameters. The aim of this study is to reduce these artifacts by performing an iterative correction and by accounting for the 3 materials soft tissue, bone, and iodine. Beam hardening corrections are either implemented as simple precorrections which cannot account for higher order beam hardening effects, or as iterative approaches that are based on segmenting the original image into material distribution images. Conventional segmentation algorithms fail to clearly distinguish between iodine and bone. Our new algorithm, DIBHC, calculates the time-dependent iodine distribution by analyzing the voxel changes of a cardiac perfusion examination (typically N approximately 15 electrocardiogram-correlated scans distributed over a total scan time up to T approximately 30 s). These voxel dynamics are due to changes in contrast agent. This prior information allows to precisely distinguish between bone and iodine and is key to DIBHC where each iteration consists of a multimaterial (soft tissue, bone, iodine) polychromatic forward projection, a raw data comparison and a filtered backprojection. Simulations with a semi-anthropomorphic dynamic phantom and clinical scans using a dual source CT scanner with 2 x 128 slices, a tube voltage of 100 kV, a tube current of 180 mAs, and a rotation time of 0.28 seconds have been carried out. The uncorrected images suffer from beam hardening artifacts that appear as dark bands connecting large concentrations of iodine in the ventricle, aorta, and bony structures. The CT-values of the affected tissue are usually underestimated by roughly 20 HU although deviations of up to 61 HU have been observed. For a quantitative evaluation circular regions of interest have been analyzed. After application of DIBHC the mean values obtained deviate by only 1 HU for the simulations and the corrected values show an increase of up to 61 HU for the measurements. One iteration of DIBHC greatly reduces the beam hardening artifacts induced by the contrast agent dynamics (and those due to bone) now allowing for an improved assessment of contrast agent uptake in the myocardium which is essential for determining myocardial perfusion.Keywords
This publication has 23 references indexed in Scilit:
- Partial scan artifact reduction (PSAR) for the assessment of cardiac perfusion in dynamic phase-correlated CTMedical Physics, 2009
- Flash imaging in dual source CT (DSCT)Published by SPIE-Intl Soc Optical Eng ,2009
- Computed tomography myocardial perfusion imaging: developmental points of emphasisExpert Review of Cardiovascular Therapy, 2009
- Assessment of Perfusion by Dynamic Contrast-Enhanced Imaging Using a Deconvolution Approach Based on Regression and Singular Value DecompositionIEEE Transactions on Medical Imaging, 2004
- Perfusion CT: a worthwhile enhancement?The British Journal of Radiology, 2003
- Perfusion measurements of the brain: using dynamic CT for the quantitative assessment of cerebral ischemia in acute strokeEuropean Journal of Radiology, 1999
- Myocardial perfusion reserve: assessment with multisection, quantitative, first-pass MR imaging.Radiology, 1997
- Assessment of myocardial perfusion by magnetic resonance imagingHerz, 1997
- Contrast‐enhanced first pass myocardial perfusion imaging: Correlation between myocardial blood flow in dogs at rest and during hyperemiaMagnetic Resonance in Medicine, 1993
- First-pass nuclear magnetic resonance imaging studies using gadolinium-DTPA in patients with coronary artery diseaseJournal of the American College of Cardiology, 1991