To demonstrate key integrative advances in microscope-integrated intraoperative optical coherence tomography (iOCT) technology that will facilitate adoption and utilization during ophthalmic surgery. We developed a second-generation prototype microscope-integrated iOCT system that interfaces directly with a standard ophthalmic surgical microscope. Novel features for improved design and functionality included improved profile and ergonomics, as well as a tunable lens system for optimized image quality and heads-up display (HUD) system for surgeon feedback. Novel material testing was performed for potential suitability for OCT-compatible instrumentation based on light scattering and transmission characteristics. Prototype surgical instruments were developed based on material testing and tested using the microscope-integrated iOCT system. Several surgical maneuvers were performed and imaged, and surgical motion visualization was evaluated with a unique scanning and image processing protocol. High-resolution images were successfully obtained with the microscope-integrated iOCT system with HUD feedback. Six semi-transparent materials were characterized to determine their attenuation coefficients and scatter density with an 830 nm OCT light source. Based on these optical properties, polycarbonate was selected as a material substrate for prototype instrument construction. A surgical pick, retinal forceps, and corneal needle were constructed with semi-transparent materials. Excellent visualization of both the underlying tissues and surgical instrument were achieved on OCT cross-section. Using model eyes, various surgical maneuvers were visualized, including membrane peeling, vessel manipulation, cannulation of the subretinal space, subretinal intraocular foreign body removal, and corneal penetration. Significant iterative improvements in integrative technology related to iOCT and ophthalmic surgery are demonstrated.Keywords
This publication has 41 references indexed in Scilit:
- Multi-MHz retinal OCTBiomedical Optics Express, 2013
- Miniature real-time intraoperative forward-imaging optical coherence tomography probeBiomedical Optics Express, 2013
- Fiber-optic OCT sensor guided “SMART” micro-forceps for microsurgeryBiomedical Optics Express, 2013
- Retinal, anterior segment and full eye imaging using ultrahigh speed swept source OCT with vertical-cavity surface emitting lasersBiomedical Optics Express, 2012
- Real-time three-dimensional Fourier-domain optical coherence tomography video image guided microsurgeriesJournal of Biomedical Optics, 2012
- Analysis of Pars Plana Vitrectomy for Optic Pit–Related Maculopathy With Intraoperative Optical Coherence TomographyJAMA Ophthalmology, 2011
- FEASIBILITY OF INTRASURGICAL SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHYRetina, 2011
- Integration of a Spectral Domain Optical Coherence Tomography System into a Surgical Microscope for Intraoperative ImagingInvestigative Opthalmology & Visual Science, 2011
- Insights into Advanced Retinopathy of Prematurity Using Handheld Spectral Domain Optical Coherence Tomography ImagingOphthalmology, 2009
- INTRAOPERATIVE USE OF HANDHELD SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY IMAGING IN MACULAR SURGERYRetina, 2009