Far Cortical Locking Can Reduce Stiffness of Locked Plating Constructs While Retaining Construct Strength
- 1 August 2009
- journal article
- Published by Ovid Technologies (Wolters Kluwer Health) in Journal of Bone and Joint Surgery
- Vol. 91 (8), 1985-1994
- https://doi.org/10.2106/jbjs.h.01038
Abstract
Several strategies to reduce construct stiffness have been proposed to promote secondary bone healing following fracture fixation with locked bridge plating constructs. However, stiffness reduction is typically gained at the cost of construct strength. In the present study, we tested whether a novel strategy for stiffness reduction, termed far cortical locking, can significantly reduce the stiffness of a locked plating construct while retaining its strength. Locked plating constructs and far cortical locking constructs were tested in a diaphyseal bridge plating model of the non-osteoporotic femoral diaphysis to determine construct stiffness in axial compression, torsion, and bending. Subsequently, constructs were dynamically loaded until failure in each loading mode to determine construct strength and failure modes. Finally, failure tests were repeated in a validated model of the osteoporotic femoral diaphysis to determine construct strength and failure modes in a worst-case scenario of bridge plating in osteoporotic bone. Compared with the locked plating constructs, the initial stiffness of far cortical locking constructs was 88% lower in axial compression (p < 0.001), 58% lower in torsion (p < 0.001), and 29% lower in bending (p < 0.001). Compared with the locked plating constructs, the strength of far cortical locking constructs was 7% lower (p = 0.005) and 16% lower (p < 0.001) under axial compression in the non-osteoporotic and osteoporotic diaphysis, respectively. However, far cortical locking constructs were 54% stronger (p < 0.001) and 9% stronger (p = 0.04) under torsion and 21% stronger (p < 0.001) and 20% stronger (p = 0.02) under bending than locked plating constructs in the non-osteoporotic and osteoporotic diaphysis, respectively. Within the initial stiffness range, far cortical locking constructs generated nearly parallel interfragmentary motion. Locked plating constructs generated significantly less motion at the near cortex adjacent to the plate than at the far cortex (p < 0.01). Far cortical locking significantly reduces the axial stiffness of a locked plating construct. This gain in flexibility causes only a modest reduction in axial strength and increased torsional and bending strength.Keywords
This publication has 54 references indexed in Scilit:
- Treatment of acute distal femur fractures above a total knee arthroplasty: Systematic review of 415 cases (1981–2006)Acta Orthopaedica, 2008
- A surrogate long-bone model with osteoporotic material properties for biomechanical testing of fracture implantsJournal of Biomechanics, 2007
- Internal plate fixation of fractures: short history and recent developmentsJournal of Orthopaedic Science, 2006
- Less Invasive Stabilization of Complex Tibial Plateau FracturesJournal of Orthopaedic Trauma, 2004
- Unstable Proximal Extraarticular Tibia FracturesJournal of Orthopaedic Trauma, 2004
- The influence of cyclic compression and distraction on the healing of experimental tibial fracturesJournal of Orthopaedic Research, 2004
- A Comparative Biomechanical Evaluation of a Noncontacting Plate and Currently Used Devices for Tibial FixationThe Journal of Trauma and Acute Care Surgery, 1996
- A Mechanical Comparison of the Dynamic Compression Plate, Limited Contact-Dynamic Compression Plate, and Point Contact FixatorJournal of Orthopaedic Trauma, 1995
- A Comparison of Unicortical and Bicortical End Screw Attachment of Fracture Fixation PlatesJournal of Orthopaedic Trauma, 1992
- External Skeletal FixationJournal of Orthopaedic Trauma, 1988