Seismic Test Methods for Architectural Glazing Systems

Abstract
An ongoing effort is being made at the University of Missouri-Rolla to develop standard laboratory test methods and codified design procedures for architectural glass under seismic loadings. Recent laboratory work has yielded some promising results regarding the development of an appropriate seismic test method for architectural glass, as well as identifying ultimate limit states that quantify the seismic performance and damage thresholds of various glass types. Specifically, a straightforward “crescendo-like” in-plane dynamic racking test, performed at a constant frequency, has been employed successfully. Two ultimate limit states for architectural glass have been defined: (1) a lower ultimate limit state corresponding to major glass crack pattern formation; and (2) an upper limit state corresponding to significant glass fallout. Early crescendo tests have yielded distinct and repeatable ultimate limit state data for various storefront glass types tested under dynamic racking motions. Crescendo tests will also be used to identify and quantify serviceability limit states for architectural glass and associated glazing components under dynamic loadings. These limit state data will support the development of rational design procedures for architectural glass under seismic loadings.