Ambulatory blood pressure monitoring predicts cardiovascular events in treated hypertensive patients – an Anglo-Scandinavian cardiac outcomes trial substudy
- 1 April 2009
- journal article
- research article
- Published by Ovid Technologies (Wolters Kluwer Health) in Journal of Hypertension
- Vol. 27 (4), 876-885
- https://doi.org/10.1097/hjh.0b013e328322cd62
Abstract
Results of the Anglo-Scandinavian cardiac outcomes trial-blood pressure lowering arm (ASCOT-BPLA) showed significantly lower rates of coronary and stroke events in individuals allocated an amlodipine-perindopril combination drug regimen than in those allocated an atenolol-thiazide combination drug regimen. The aims of the ambulatory blood pressure (ABP) substudy of ASCOT were to examine the impact of the two blood pressure (BP)- lowering regimens on ambulatory pressures, test to what extent the between-treatment differences in cardiovascular outcome could be attributed to differences in ABP and assess whether ABP provides predictive information additional to that of clinic blood pressure (CBP) in treated hypertensive patients. One thousand, nine hundred and five patients from four ASCOT centres had repeated ABPs performed over a median follow-up period of 5.5 years. As in the whole ASCOT population, CBP values were lower in amlodipine-perindopril-treated patients compared with those treated with atenolol-thiazide [between-regimen difference [95% confidence intervals (CIs)]]: [-1.5 (-2.4 to -0.5)/-1.2 (-1.8 to +0.5) mmHg]. Daytime BP during follow-up was higher in patients treated with amlodipine-perindopril therapy [+1.1 (0.1-2.1)/+1.6 (0.8-2.3) mmHg]; night-time systolic, but not diastolic BP, was lower in patients treated with amlodipine-perindopril therapy [-2.2 (-3.4 to +0.9)/+0.8 (0.0-1.6) mmHg]. The relative risk of a cardiovascular event associated with a 1 SD increment in accumulated mean BP was 1.35 (1.18-1.53) for clinic systolic BP, 1.30 (1.14-1.49) for daytime systolic BP and 1.42 (1.24-1.62) for night-time systolic BP. With adjustment for baseline variables, treatment regimen and clinic systolic BP, the hazard ratios were 1.17 (1.00-1.36) and 1.25 (1.08-1.47) for daytime and night-time systolic BP, respectively. The between-regimen adjusted hazard ratio for cardiovascular events (amlodipine-perindopril therapy versus atenolol-thiazide therapy) was 0.74 (0.55-1.01) and increased to 0.81 (0.60-1.10) after further adjustment for clinic systolic BP. Further, adjustment for night-time systolic BP increased the hazard ratio to 0.85 (0.62-1.16). The amlodipine-perindopril and atenolol-thiazide regimens had different effects on daytime and night-time ABP, which may have contributed to the lower rates of events in patients treated with amlodipine-perindopril therapy. Both CBP and ABP were significantly associated with rates of cardiovascular events. ABP nocturnal pressures provided complimentary and incremental utility over CBP in the prediction of cardiovascular risk in treated hypertensive patients. These data support the use of ABP to assess the effect of antihypertensive treatment in clinical practice.Keywords
This publication has 22 references indexed in Scilit:
- Is the Case for ABPM as a Routine Investigation in Clinical Practice Not Overwhelming?Hypertension, 2007
- Prevention of cardiovascular events with an antihypertensive regimen of amlodipine adding perindopril as required versus atenolol adding bendroflumethiazide as required, in the Anglo-Scandinavian Cardiac Outcomes Trial-Blood Pressure Lowering Arm (ASCOT-BPLA): a multicentre randomised controlled trialThe Lancet, 2005
- Role of blood pressure and other variables in the differential cardiovascular event rates noted in the Anglo-Scandinavian Cardiac Outcomes Trial-Blood Pressure Lowering Arm (ASCOT-BPLA)The Lancet, 2005
- Superiority of Ambulatory Over Clinic Blood Pressure Measurement in Predicting MortalityHypertension, 2005
- European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure measurementJournal of Hypertension, 2003
- Comparative Effects of Ramipril on Ambulatory and Office Blood PressuresHypertension, 2001
- Ambulatory blood pressure monitoring and 24-h blood pressure control as predictors of outcome in treated hypertensive patientsJournal of Human Hypertension, 2001
- Prognostic Value of Ambulatory Blood Pressure Monitoring in Refractory HypertensionHypertension, 1998
- 19 An accurate automated device for home blood pressure measurement at last! The Omron HEM-705CPJournal of Hypertension, 1994
- Accuracy of the SpaceLabs 90207 determined by the British Hypertension Society ProtocolJournal of Hypertension, 1991