PERFORATION OF THE RIGHT INNOMINATE VEIN BY CENTRAL VENOUS POLYETHYLENE CATHETER

Abstract
A case of hydrothorax secondary to perforation of the right innominate vein by a central venous polyethylene catheter is presented. Recommendations for the safe clinical management of such monitors arc detailed