Intrasaccular Flow-Disruption Treatment of Intracranial Aneurysms: Preliminary Results of a Multicenter Clinical Study
Open Access
- 7 June 2012
- journal article
- clinical trial
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 33 (7), 1232-1238
- https://doi.org/10.3174/ajnr.a3191
Abstract
BACKGROUND AND PURPOSE: The endovascular treatment of intracranial aneurysms with unfavorable anatomy (large aneurysms, wide-neck) is frequently challenging and is also associated with a high incidence of significant recurrences. The WEB, an intrasaccular flow disrupter, was designed for use in this type of aneurysm. We report our early experience with this device in this multicenter study. MATERIALS AND METHODS: Twenty patients with 21 aneurysms were treated by using the WEB in 3 European centers. The ability to successfully deploy the WEB, immediate posttreatment angiographic results, adverse events, clinical outcome, and angiographic follow-up results were recorded. RESULTS: Aneurysm location was the ICA (4/21, 19.1%), MCA (8/21, 38.1%), AcomA (5/21, 23.8%), and BA (4/21, 19.1%). No treatment failures were reported. Treatment was performed exclusively with the WEB in 16/21 (76.2%) patients. Additional treatment (coiling and/or stent placement) was used in 5/21 (23.8%) patients. One patient (4.8%) experienced transient clinical worsening (mRS 1 at 1 month, mRS 0 at 3 months) related to a thromboembolic event. Inadvertent detachment of the WEB was observed, and the WEB was retrieved in 1 patient, without adverse effects. In the short-term follow-up (2–8 months), adequate occlusion (total occlusion or neck remnant) was observed in 80.0% of aneurysms. CONCLUSIONS: Intrasaccular flow disruption is a new endovascular approach for aneurysm treatment. In our preliminary experience, this treatment was feasible and mostly used in bifurcation aneurysms (MCA, BA, ICA) with unfavorable anatomy. Further studies are needed to precisely evaluate the indications, safety, and efficacy of this new technique.Keywords
This publication has 14 references indexed in Scilit:
- Results of Embolization Used as the First Treatment Choice in a Consecutive Nonselected Population of Ruptured Aneurysms: Clinical Results of the Clarity GDC StudyNeurosurgery, 2011
- Flow diverter stents in the treatment of intracranial aneurysms: Where are we?Journal of Neuroradiology, 2011
- Safety and Efficacy of Balloon Remodeling Technique during Endovascular Treatment of Intracranial Aneurysms: Critical Review of the LiteratureAmerican Journal of Neuroradiology, 2011
- Remodeling Technique for Endovascular Treatment of Ruptured Intracranial Aneurysms Had a Higher Rate of Adequate Postoperative Occlusion than Did Conventional Coil Embolization with Comparable SafetyRadiology, 2011
- Stent-Assisted Coiling of Intracranial AneurysmsStroke, 2010
- Coiling of Intracranial AneurysmsStroke, 2009
- Y-stent-assisted coil embolization for the management of unruptured cerebral aneurysms: report of six casesActa Neurochirurgica, 2009
- Endovascular Treatment of Unruptured Intracranial Aneurysms: Comparison of Safety of Remodeling Technique and Standard Treatment with CoilsRadiology, 2009
- Immediate Clinical Outcome of Patients Harboring Unruptured Intracranial Aneurysms Treated by Endovascular ApproachStroke, 2008
- Coils or clips in subarachnoid haemorrhage?The Lancet, 2002