Effect of Live Load Surcharge on Retaining Walls and Abutments

Abstract
In the conventional design of retaining walls and bridge abutments, the lateral earth pressure due to live load surcharge is estimated by replacing the actual highway loads with a 600 mm layer of backfill. This original recommendation was made several decades ago when the highway truck loads were much lighter. A number of researchers have shown that the pressure exerted on the wall due to live load surcharge is greater near the surface and is diminished nonlinearly throughout the height of the wall. The heavier highway loads and the demonstrated nonlinear earth pressure distribution require a need for a more rational method for obtaining the equivalent height of backfill. This paper discusses theoretical background, an analytical approach to estimation of actual earth pressure, a number of innovative approaches to obtain a simplified pressure distribution, an extensive parametric study, calibration procedures for the traditional method, and recommendations.

This publication has 1 reference indexed in Scilit: