Abstract
This paper presents a new method of harmonic power detection based on the instantaneous active power in three-phase circuits, and its applications to search for dominant harmonic sources in power systems. The proposed method requires only band elimination filters and a three-phase active power meter to detect the harmonic active power, and it is able to deal with harmonic power flow more easily and precisely than a conventional meter which is based on Fourier series of single-phase circuits. In addition, measurement errors of the harmonic power are discussed theoretically. The validity of the proposed method is demonstrated by digital simulation.

This publication has 1 reference indexed in Scilit: