Effects of mechanical left ventricular unloading by impella on left ventricular dynamics in high‐risk and primary percutaneous coronary intervention patients
- 25 November 2009
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 75 (2), 187-194
- https://doi.org/10.1002/ccd.22263
Abstract
Objectives: We studied online left ventricular (LV) dynamic effects of mechanical LV unloading directly after percutaneous coronary intervention (PCI). Background: Limited clinical information is available on the direct LV dynamic consequences of LV unloading in patients undergoing high‐risk PCI and primary PCI for acute ST‐elevation myocardial infarction. Methods: The effects of the Impella LP2.5 device on LV dynamics were studied in 11 patients (elective high‐risk PCI, n = 6; primary PCI, n = 5). LV pressure and volume were continuously assessed by a pressure‐conductance catheter at 4 different support levels of the Impella, from 0 L/min at baseline to 2.5 L/min at maximal support. Results: The response to increased LV unloading was not different between both groups of patients. The pooled data showed no change on global and systolic LV function during increased LV unloading, while diastolic function showed improvement as indicated by an increased LV compliance in all patients. There was a decrease in end‐diastolic pressure from 22 ± 12 to 13 ± 9 mm Hg (P = 0.0001), in end‐diastolic elastance from 0.134 ± 0.060 to 0.091 ± 0.064 mm Hg/mL (P = 0.009), and in end‐diastolic wall stress from 84 ± 50 to 47 ± 39 mm Hg (P = 0.004). Conclusions: LV unloading decreases end‐diastolic wall stress and improves diastolic compliance dose‐dependently. Our results indicate beneficial LV unloading effects of Impella during high‐risk and primary PCI.Keywords
This publication has 29 references indexed in Scilit:
- Coronary microvascular dysfunction after myocardial infarction: increased coronary zero flow pressure both in the infarcted and in the remote myocardium is mainly related to left ventricular filling pressureHeart, 2007
- Combined Impella and Intra‐aortic Balloon Pump Support to Improve Both Ventricular Unloading and Coronary Blood Flow for Myocardial Recovery: An Experimental StudyArtificial Organs, 2007
- Time Course of Microvascular Resistance of the Infarct and Noninfarct Coronary Artery Following an Anterior Wall Acute Myocardial InfarctionThe American Journal of Cardiology, 2006
- Safety and Feasibility of Elective High-Risk Percutaneous Coronary Intervention Procedures With Left Ventricular Support of the Impella Recover LP 2.5The American Journal of Cardiology, 2006
- Beat-to-Beat Effects of Intraaortic Balloon Pump Timing on Left Ventricular Performance in Patients With Low Ejection FractionThe Annals of Thoracic Surgery, 2005
- Elective versus provisional intra-aortic balloon pumping in high-risk percutaneous transluminal coronary angioplastyAmerican Heart Journal, 2003
- Relation of Hemodynamic Variables to Augmentation of Left Anterior Descending Coronary Flow by Intraaortic Balloon Pulsation in Coronary Artery DiseaseThe American Journal of Cardiology, 1997
- Left ventricular-arterial coupling relations in the normal human heartAmerican Heart Journal, 1993
- Continuous measurement of left ventricular volume in animals and humans by conductance catheter.Circulation, 1984