Endoscopic Reconstruction of the Anterior Cruciate Ligament using Bone-Patellar Tendon-Bone Grafts Fixed with Bioabsorbable or Metal Interference Screws
- 1 August 2005
- journal article
- clinical trial
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 33 (8), 1160-1165
- https://doi.org/10.1177/0363546504272264
Abstract
During the past decade, bioabsorbable interference screws have become increasingly popular in endoscopic reconstructions of the anterior cruciate ligament. With these screws, there is no need for a second operation for removal and no complicating factor if later revision surgery is necessary. Several pullout studies have found similar results between metal and bioabsorbable interference screws; however, few studies have investigated the clinical outcome. There is no difference in the clinical outcome of bioabsorbable interference screws compared with metal screws. Randomized controlled clinical trial; Level of evidence, 1. Forty-one patients were randomized for the use of either metal interference screws (20 patients) or bioabsorbable poly-L-lactic acid screws (21 patients). The patients were followed with clinical examinations at 6, 12, and 24 weeks and at 1 and 2 years postoperatively. Subjective knee function was better in the patients in the metal screw group; they had less pain at rest, a higher Tegner score, a higher Lysholm score, and better subjective knee function at 2 years compared to the bioabsorbable screw group. However, there was no difference in stability between the groups. Because of the inferior results in the bioabsorbable screw group in our study, and until larger studies show otherwise, we do not find the advantages of using bioabsorbable screws sufficient to warrant the routine use of poly-L-lactic acid screws in anterior cruciate ligament reconstructions.Keywords
This publication has 26 references indexed in Scilit:
- Insertion torque pullout strength relationship of soft tissue tendon graft tibia tunnel fixation with a bioabsorbable interference screwArthroscopy: The Journal of Arthroscopic & Related Surgery, 2004
- Anterior Cruciate Ligament Reconstruction with Autogenous Patellar Tendon Graft Followed by Accelerated RehabilitationThe American Journal of Sports Medicine, 1997
- Metal and biodegradable interference screws: Comparison of failure strengthArthroscopy: The Journal of Arthroscopic & Related Surgery, 1996
- Comparison of Failure Strength Between Metallic and Absorbable Interference ScrewsThe American Journal of Sports Medicine, 1996
- Activation of the complement system and adverse effects of biodegradable pins of poly-lactic acid (Biofix®) in osteochondritis dissecansActa Orthopaedica, 1994
- Severe aseptic synovitis of the knee after biodegradable internal fixationActa Orthopaedica, 1992
- Followup of the acute nonoperated isolated anterior cruciate ligament tearThe American Journal of Sports Medicine, 1986
- Instrumented measurement of anterior knee laxity in patients with acute anterior cruciate ligament disruptionThe American Journal of Sports Medicine, 1985
- Rating Systems in the Evaluation of Knee Ligament InjuriesClinical Orthopaedics and Related Research, 1985
- Evaluation of knee ligament surgery results with special emphasis on use of a scoring scaleThe American Journal of Sports Medicine, 1982