The Impact of Height on Indoor Positioning With Magnetic Fields
- 1 January 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456), 1-19
- https://doi.org/10.1109/TIM.2021.3059317
Abstract
Steel studs, heating, ventilation, and air conditioning (HVAC) systems, rebar, and many other building components produce spatially varying magnetic fields. Magnetometers can measure these fields and can be used in combination with inertial sensors for indoor positioning of robots and handheld devices, such as smartphones. Current methods of localization and mapping with magnetometers are often based on the simplifying assumption that magnetic fields do not vary with height. In this article, through the analysis of a large data set collected across three buildings on the University of Illinois campus, we quantify the extent to which this "planar assumption" is likely to be violated and examine the consequences for indoor positioning. First, we show that out-of-plane variations in the magnetic field were significant at over half the locations where magnetometer measurements were taken. Second, we show that absolute trajectory error in positioning was low when both localization and mapping were based on magnetometer measurements taken at the same height, but that error increased significantly with even small differences between these heights. Third, we show that the choice of height at which to take measurementsif this height was kept the same for both localization and mapping-had no significant impact on absolute trajectory error when averaged across a given set of trajectories although some trajectories existed for which different measurement heights led to significantly different errors. Fourth, we show that absolute trajectory error decreased when magnetometer measurements were aggregated across a small range of heights to produce a single, planar map and when measurements at the median height were used for localization.Funding Information
- National Science Foundation (14-46765, 14-27111, 15-44999)
This publication has 63 references indexed in Scilit:
- Magnetic field constraints and sequence-based matching for indoor pose graph SLAMRobotics and Autonomous Systems, 2015
- Indoor Mobile Robot Localization and Mapping Based on Ambient Magnetic Fields and Aiding Radio SourcesIEEE Transactions on Instrumentation and Measurement, 2014
- Mapping, Planning, and Sample Detection Strategies for Autonomous ExplorationJournal of Field Robotics, 2013
- LocateMeACM Transactions on Intelligent Systems and Technology, 2013
- Development of a Mobile Robot to Run in Tsukuba Challenge 2010Advanced Robotics, 2012
- Navigation Using an Environmental Magnetic Field for Outdoor Autonomous Mobile RobotsAdvanced Robotics, 2011
- Global indoor self-localization based on the ambient magnetic fieldRobotics and Autonomous Systems, 2009
- Economic evaluation of shelf‐space management in grocery storesAgribusiness, 2007
- Development of a Tiny Orientation Estimation Device to Operate under Motion and Magnetic DisturbanceThe International Journal of Robotics Research, 2007
- Scalar calibration of vector magnetometersMeasurement Science and Technology, 2000