In this study, a novel sorbent material bearing a bis(aldimine) group was designed and successfully synthesized by covalently bonding a 2-[N,N′-bis(salicylaldimine)]aminoethyl amine ligand to the silica gel surface that was characterized by carbon, hydrogen, and nitrogen elemental analysis, thermogravimetric analysis, and the Fourier transform infrared spectroscopy technique. The sorbent was used for the online solid-phase extraction (SPE) of Cd(II), Cu(II), and Co(II) ions for their determination at trace concentration levels by flame atomic absorption spectrometry. The effective factors for the online SPE such as the pH and the flow rate of the sample solution, and type, volume, and flow rate of eluent were investigated. The concentration levels of Cd(II), Cu(II), and Co(II) were measured in certified reference materials including Virginia tobacco leaves (CTA-VTL-2) and water-trace elements (NWTM-15.2) to validate this method. The metal levels in environmental water were determined by this method, and the values were checked by spiking and recovery experiments and independent analysis by inductively coupled plasma-mass spectrometry. The adsorption capacities of the sorbent were found to be 41.2, 31.6, and 25.6 mg/g for Cd(II), Cu(II), and Co(II), respectively. This method was also successfully used for the determination of Cd(II), Cu(II), and Co(II) concentrations in rice and molasses.Keywords
Funding Information
- Sakarya Üniversitesi (2012-50-02-036)
This publication has 44 references indexed in Scilit:
- Cu2+‐imprinted cross‐linked chitosan resin as micro‐column packing materials for online chemiluminescence determination of trace copperLuminescence, 2011
- Silica gel–polyethylene glycol as a new adsorbent for solid phase extraction of cobalt and nickel and determination by flame atomic absorption spectrometryTalanta, 2010
- Preparation of a new Cd(II)-imprinted polymer and its application to determination of cadmium(II) via flow-injection-flame atomic absorption spectrometryTalanta, 2010
- Tris(2-aminoethyl) amine functionalized silica gel for solid-phase extraction and preconcentration of Cr(III), Cd(II) and Pb(II) from watersJournal of Hazardous Materials, 2008
- Determination of cobalt, copper and nickel in food samples after pre-concentration on a new pyrocatechol-functionalized polyurethane foam sorbentReactive and Functional Polymers, 2007
- Preconcentration system for cadmium and lead determination in environmental samples using polyurethane foam/Me-BTANCJournal of Hazardous Materials, 2006
- Amberlite XAD-2 functionalized with 2-aminothiophenol as a new sorbent for on-line preconcentration of cadmium and copperTalanta, 2005
- Simultaneous on-line preconcentration and determination of trace metals in environmental samples by flow injection combined with inductively coupled plasma mass spectrometry using a nanometer-sized alumina packed micro-columnAnalytica Chimica Acta, 2005
- Use of silica gel chemically modified with zirconium phosphate for preconcentration and determination of lead and copper by flame atomic absorption spectrometryTalanta, 2003
- Application of iminodiacetate chelating resin muromac A-1 in on-line preconcentration and inductively coupled plasma optical emission spectroscopy determination of trace elements in natural watersSpectrochimica Acta Part B: Atomic Spectroscopy, 2003