Towards measuring the effect of flow in blood T 1 assessed in a flow phantom and in vivo
Open Access
- 11 March 2020
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (9), 095001
- https://doi.org/10.1088/1361-6560/ab7ef1
Abstract
Measurement of the blood T1 time using conventional myocardial T1 mapping methods has gained clinical significance in the context of extracellular volume (ECV) mapping and synthetic hematocrit (Hct). However, its accuracy is potentially compromised by in-flow of non-inverted/non-saturated spins and in-flow of spins which are not partially saturated from previous imaging pulses. Bloch simulations were used to analyze various flow effects separately. T1 measurements of gadolinium doped water were performed using a flow phantom with adjustable flow velocities at 3T. Additionally, in vivo blood T1 measurements were performed in 6 healthy subjects. To study the T1 time as a function of the instantaneous flow velocity, T1 times were evaluated in an axial imaging slice of the descending aorta. Simulation results show more than 30% loss in accuracy for 10% non-prepared in-flowing spins. However, in- and out-flow to the imaging plane only demonstrated minor impact on the T1 time. Phantom T1 times were decreased by up to 200 ms in the flow phantom, due to in-flow of non-prepared spins. High flow velocities cause in-flow of spins that lack partial saturation from the imaging pulses but only lead to negligible T1 time deviation (less than 30 ms). In vivo measurements confirm a substantial variation of the T1 time depending on the flow velocity. The highest aortic T1 times are observed at the time point of minimal flow with increased flow velocity leading to reduction of the measured T1 time at peak velocity. In this work we attempt to dissect the effects of flow on T1 times, by using simulations, well-controlled, simplified phantom setup and the linear flow pattern in the descending aorta in vivo.This publication has 43 references indexed in Scilit:
- Influence of Off-resonance in myocardial T1-mapping using SSFP based MOLLI methodJournal of Cardiovascular Magnetic Resonance, 2013
- T1 and extracellular volume mapping in the heart: estimation of error maps and the influence of noise on precisionJournal of Cardiovascular Magnetic Resonance, 2013
- Correction with blood T1 is essential when measuring post-contrast myocardial T1 value in patients with acute myocardial infarctionJournal of Cardiovascular Magnetic Resonance, 2013
- Extracellular volume imaging by magnetic resonance imaging provides insights into overt and sub-clinical myocardial pathologyEuropean Heart Journal, 2012
- Extracellular volume fraction mapping in the myocardium, part 1: evaluation of an automated methodJournal of Cardiovascular Magnetic Resonance, 2012
- Cardiovascular magnetic resonance by non contrast T1-mapping allows assessment of severity of injury in acute myocardial infarctionJournal of Cardiovascular Magnetic Resonance, 2012
- Fast measurement of bloodT1in the human jugular vein at 3 TeslaMagnetic Resonance in Medicine, 2010
- Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathholdJournal of Cardiovascular Magnetic Resonance, 2010
- Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heartMagnetic Resonance in Medicine, 2004
- Quantification of T1 values by SNAPSHOT-FLASH NMR imagingJournal of Magnetic Resonance (1969), 1992