Old enemy, new threat: you can’t solve today’s problems with yesterday’s solution
- 3 February 2021
- journal article
- research article
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 41 (2), 452-458
- https://doi.org/10.1088/1361-6498/abe2ba
Abstract
The radiation protection principles of justification, optimization, and dose limitation as enumerated by the International Commission on Radiological Protection (ICRP) have been guiding light for the profession for over three decades. The dose limitation does not apply to medical exposure but keeping patients' doses low is achieved through optimization, particularly by developing and using diagnostic reference levels (DRLs). There are new findings that demonstrate that despite using the best possible approaches to justification and optimization including as well use of DRLs, a very large number of patients are receiving doses in excess of 100 mSv of effective dose or organ doses exceeding 100 mGy. A non-ignorable fraction of patients is receiving such high doses in a single day. The magnitude of such patients creates the need for a relook into the principles with the intent to what can be done to attend to today's problems. A look at other areas such as approaches, and principles used in the pharmaceutical industry and in traffic management throws some light into what can be learnt from these examples. It appears that the system needs to be enriched to deal with the protection of the individual patient. The currently available approaches and even the principles are largely based on the protection of the population or group of patients. The third level of justification for individual needs further refinement to take into account series of imaging many patients are needing, and cumulative radiation doses involved, many of which happen in a short duration of one to five years. There is every likelihood of patient radiation doses continuing to increase further that underscores the need for timely attention. This paper provides several suggestions to deal with the situation.Keywords
This publication has 29 references indexed in Scilit:
- Multicentric study of patients receiving 50 or 100 mSv in a single day through CT imaging-frequency determination and imaging protocols involvedEuropean Radiology, 2021
- Analysis of patients receiving ≥ 100 mSv during a computed tomography interventionEuropean Radiology, 2020
- Higher patient doses through X-ray imaging proceduresPhysica Medica, 2020
- Estimates of the number of patients with high cumulative doses through recurrent CT exams in 35 OECD countriesPhysica Medica, 2020
- Recurrent imaging procedures with ionising radiation on the same patient. Should we pay more attention?Journal of Radiological Protection, 2020
- Patients undergoing recurrent CT exams: assessment of patients with non-malignant diseases, reasons for imaging and imaging appropriatenessEuropean Radiology, 2019
- Patients undergoing recurrent CT scans: assessing the magnitudeEuropean Radiology, 2019
- Multinational data on cumulative radiation exposure of patients from recurrent radiological procedures: call for actionEuropean Radiology, 2019
- Patient radiation exposure and dose tracking: a perspectiveJournal of Medical Imaging, 2017
- Recurrent CT, Cumulative Radiation Exposure, and Associated Radiation-induced Cancer Risks from CT of AdultsRadiology, 2009