Positive End-Expiratory Pressure in Newborn Resuscitation Around Term: A Randomized Controlled Trial
- 1 October 2020
- journal article
- research article
- Published by American Academy of Pediatrics (AAP) in PEDIATRICS
- Vol. 146 (4)
- https://doi.org/10.1542/peds.2020-0494
Abstract
BACKGROUND: International guidelines for resuscitation recommend using positive end-expiratory pressure (PEEP) during ventilation of preterm newborns. Reliable PEEP-valves for self-inflating bags have been lacking, and effects of PEEP during resuscitation of term newborns are insufficiently studied. The objective was to determine if adding a new PEEP valve to the bag-mask during resuscitation of term and near-term newborns could improve heart rate response. METHODS: This randomized controlled trial was performed at Haydom Lutheran Hospital in Tanzania (September 2016 to June 2018). Helping Babies Breathe–trained midwives performed newborn resuscitation using self-inflating bags with or without a new, integrated PEEP valve. All live-born newborns who received bag-mask ventilation at birth were eligible. Heart rate response measured by ECG was the primary outcome, and clinical outcome and ventilation data were recorded. RESULTS: Among 417 included newborns (median birth weight 3200 g), 206 were ventilated without and 211 with PEEP. We found no difference in heart rate response. Median (interquartile range) measured PEEP in the PEEP group was 4.7 (2.0–5.6) millibar. The PEEP group received lower tidal volumes (4.9 [1.9–8.2] vs 6.3 [3.9–10.5] mL/kg; P = .02) and had borderline lower expired CO2 (2.9 [1.5–4.3] vs 3.3 [1.9–5.0] %; P = .05). Twenty four-hour mortality was 9% in both groups. CONCLUSIONS: We found no evidence for improved heart rate response during bag-mask ventilation with PEEP compared with no PEEP. The PEEP valve delivered a median PEEP within the intended range. The findings do not support routine use of PEEP during resuscitation of newborns around term.This publication has 51 references indexed in Scilit:
- Expired CO2 Levels Indicate Degree of Lung Aeration at BirthPLOS ONE, 2013
- Birth Asphyxia: A Major Cause of Early Neonatal Mortality in a Tanzanian Rural HospitalPEDIATRICS, 2012
- Oxygenation with T-Piece versus Self-Inflating Bag for Ventilation of Extremely Preterm Infants at Birth: A Randomized Controlled TrialThe Journal of Pediatrics, 2011
- Assessment of tidal volume and gas leak during mask ventilation of preterm infants in the delivery roomArchives of Disease in Childhood: Fetal & Neonatal, 2010
- Should the Neopuff T-piece resuscitator be restricted to frequent users?Acta Paediatrica, 2010
- The effect of a PEEP valve on a Laerdal neonatal self‐inflating resuscitation bagJournal of Paediatrics and Child Health, 2010
- Neonatal resuscitation in low-resource settings: What, who, and how to overcome challenges to scale up?International Journal of Gynecology & Obstetrics, 2009
- Reliability of Two Common PEEP-Generating Devices used in Neonatal ResuscitationKlinische Padiatrie, 2009
- Reducing Lung Injury during Neonatal Resuscitation of Preterm InfantsThe Journal of Pediatrics, 2008
- Neonatal resuscitation 1: a model to measure inspired and expired tidal volumes and assess leakage at the face maskArchives of Disease in Childhood: Fetal & Neonatal, 2005