Abstract
In this paper, an ultra-low power analog-to-digital converter (ADC) is proposed which is working based on level-crossing sampling. Level-crossing sampling is a data-compression technique utilizing specially for low-power implementation of biomedical signal acquisition systems. Despite the non-uniform nature of level-crossing sampling, the proposed ADC is implemented synchronously which leads to much lower power consumption and improved reliability. Accuracy of the ADC is improved by using a modified structure for dynamic comparators. A low-cost tuning circuit is also proposed for canceling a great portion of the background noise, which leads to a more efficient compression. The ADC is designed for ECG signal acquisition and implemented in 0.18 μm CMOS technology which consumes an ultra low power of 28 nW for 1.8 V supply voltage.Keywords
This publication has 13 references indexed in Scilit:
- An event-based ECG-monitoring and QRS-detection system based on level-crossing samplingPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2017
- A fully-synchronous offset-insensitive level-crossing analog-to-digital converterPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2017
- Pseudo Asynchronous Level Crossing adc for ecg Signal AcquisitionIEEE Transactions on Biomedical Circuits and Systems, 2017
- A 2.89 μW Dry-Electrode Enabled Clockless Wireless ECG SoC for Wearable ApplicationsIEEE Journal of Solid-State Circuits, 2016
- A 300-mV 220-nW Event-Driven ADC With Real-Time QRS Detection for Wearable ECG SensorsIEEE Transactions on Biomedical Circuits and Systems, 2014
- A Level-Crossing Based QRS-Detection Algorithm for Wearable ECG SensorsIEEE Journal of Biomedical and Health Informatics, 2013
- Detailed study of the time estimation in level-crossing analog-to-digital convertersPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2013
- A Sub-Microwatt Asynchronous Level-Crossing ADC for Biomedical ApplicationsIEEE Transactions on Biomedical Circuits and Systems, 2013
- Continuous Time Level Crossing Sampling ADC for Bio-Potential Recording SystemsIEEE Transactions on Circuits and Systems I: Regular Papers, 2013
- A 53-nW 9.1-ENOB 1-kS/s SAR ADC in 0.13-$\mu$m CMOS for Medical Implant DevicesIEEE Journal of Solid-State Circuits, 2012