Model Based Design of a Low Cost and Compliant Low Profile Prosthetic Foot
- 14 October 2021
- journal article
- research article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 144 (3)
- https://doi.org/10.1115/1.4052369
Abstract
This paper describes the design of a simple and low cost compliant low profile prosthetic foot based on a cantilevered beam of uniform strength. The prosthetic foot is developed such that the maximum stress experienced by the beam is distributed approximately evenly across the length of the beam. Due to this stress distribution, the prosthetic foot exhibits compliant behavior not achievable through standard design approaches (e.g. designs based on simple cantilevered beams). Additionally, due to its simplicity and use of flat structural members, the foot can be manufactured at low cost. An analytical model of the compliant behavior of the beam is developed that facilitates rapid design changes to vary foot size and stiffness. A characteristic prototype was designed and constructed to be used in both a benchtop quasistatic loading test as well as a dynamic walking test for validation. The model predicted the rotational stiffness of the prototype with 5% error. Furthermore, the prototype foot was tested alongside two commercially available prosthetic feet (a low profile foot and an energy storage and release foot) in level walking experiments with a single study participant. The prototype foot displayed the lowest stiffness of the three feet (6.0, 7.1, and 10.4 Nm/deg for the prototype foot, the commercial low profile foot, and the energy storage and release foot, respectively). This foot design approach and accompanying model may allow for compliant feet to be developed for individuals with long residual limbs.Keywords
This publication has 28 references indexed in Scilit:
- The effects of prosthetic ankle stiffness on ankle and knee kinematics, prosthetic limb loading, and net metabolic cost of trans-tibial amputee gaitClinical Biomechanics, 2014
- Novel Method to Evaluate Angular Stiffness of Prosthetic Feet From Linear Compression TestsJournal of Biomechanical Engineering, 2013
- Estimation of Quasi-Stiffness and Propulsive Work of the Human Ankle in the Stance Phase of WalkingPLOS ONE, 2013
- Gait speed and gender effects on center of pressure progression during normal walkingGait & Posture, 2013
- Optimization of Prosthetic Foot Stiffness to Reduce Metabolic Cost and Intact Knee Loading During Below-Knee Amputee Walking: A Theoretical StudyJournal of Biomechanical Engineering, 2012
- An Active Foot-Ankle Prosthesis With Biomechanical Energy RegenerationJournal of Medical Devices, 2010
- Estimating the Prevalence of Limb Loss in the United States: 2005 to 2050Archives of Physical Medicine and Rehabilitation, 2008
- The advantages of a rolling foot in human walkingJournal of Experimental Biology, 2006
- Energy storage and return prostheses: does patient perception correlate with biomechanical analysis?Clinical Biomechanics, 2002
- Bioenergetic comparison of a new energy-storing foot and SACH foot in traumatic below-knee vascular amputationsArchives of Physical Medicine and Rehabilitation, 1995