Measurement of ammonia, amines and iodine compounds using protonated water cluster chemical ionization mass spectrometry
Open Access
- 19 May 2020
- journal article
- research article
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 13 (5), 2501-2522
- https://doi.org/10.5194/amt-13-2501-2020
Abstract
Here we describe the design and performance of a new water cluster chemical ionization-atmospheric pressure interface time-of-flight mass spectrometer (CI-APi-TOF). The instrument selectively measures trace gases with high proton affinity such as ammonia and dimethylamine, which are important for atmospheric new particle formation and growth. Following the instrument description and characterization, we demonstrate successful measurements at the CERN CLOUD (Cosmics Leaving OUtdoor Droplets) chamber where very low ammonia background levels of similar to 4 pptv were achieved (at 278K and 80% RH). The limit of detection of the water cluster CI-APi-TOF is estimated to be similar to 0.5 pptv for ammonia. Although no direct calibration was performed for dimethylamine (DMA), we estimate its detection limit is at least 3 times lower. Due to the short ion-molecule reaction time and high reagent ion concentrations, ammonia mixing ratios up to at least 10 ppbv can be measured with the instrument without significant reagent ion depletion. Besides the possibility to measure compounds like ammonia and amines (dimethylamine), we demonstrate that the ionization scheme is also suitable for the measurement of trace gases containing iodine. During CLOUD experiments to investigate the formation of new particles from I-2, many different iodine-containing species were identified with the water cluster CI-APi-TOF. The compounds included iodic acid and neutral molecular clusters containing up to four iodine atoms. However, the molecular structures of the iodine-containing clusters are ambiguous due to the presence of an unknown number of water molecules. The quantification of iodic acid (HIO3) mixing ratios is performed from an intercomparison with a nitrate CI-APi-TOF. Using this method the detection limit for HIO3 can be estimated as 0.007 pptv. In addition to presenting our measurements obtained at the CLOUD chamber, we discuss the applicability of the water cluster Ci-APi-TOF for atmospheric measurements.This publication has 75 references indexed in Scilit:
- Temperature uniformity in the CERN CLOUD chamberAtmospheric Chemistry and Physics, 2017
- New particle formation in the free troposphere: A question of chemistry and timingScience, 2016
- Statistical precision of the intensities retrieved from constrained fitting of overlapping peaks in high-resolution mass spectraAtmospheric Chemistry and Physics, 2015
- High-resolution chemical ionization mass spectrometry (ToF-CIMS): application to study SOA composition and processingAtmospheric Chemistry and Physics, 2013
- Molecular understanding of sulphuric acid–amine particle nucleation in the atmosphereNature, 2013
- On-line determination of ammonia at low pptv mixing ratios in the CLOUD chamberAtmospheric Chemistry and Physics, 2012
- A Chemical Ionization Mass Spectrometer for ambient measurements of AmmoniaAtmospheric Chemistry and Physics, 2010
- Cavity enhanced absorption spectroscopy measurements of pressure-induced broadening and shift coefficients in the υ 1+υ 3 combination band of ammoniaApplied Physics B Laser and Optics, 2008
- Chemical ionization mass spectrometer for long-term measurements of atmospheric OH and H2SO4International Journal of Mass Spectrometry, 2000
- Adsorption and dissociation of Ammonia on the hydroxylated surface of magnesium oxide powdersJournal of the Chemical Society, Faraday Transactions 1: Physical Chemistry in Condensed Phases, 1987