Intensity modulated Ir-192 brachytherapy using high-Z 3D printed applicators
- 31 July 2020
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (15), 155018
- https://doi.org/10.1088/1361-6560/ab9b54
Abstract
Gynecologic cancers are often asymmetric, yet current Ir-192 brachytherapy techniques provide only limited radial modulation of the dose. The shielded solutions investigated here solve this by providing the ability to modulate between highly asymmetric and radially symmetric dose distributions at a given location. To find applicator designs that can modulate between full dose and less than 50% dose, at the dimensions of the urethra, a 2D calculation algorithm was developed to narrow down the search space. Two shielding design types were then further investigated using Monte Carlo and Boltzmann-solver dose calculation algorithms. 3D printing techniques using ISO 10993 certified biocompatible plastics and 3D printable tungsten-loaded plastics were tested. It was also found that shadowing effects set by the shape of the shielding cannot be easily modulated out, hence careful design is required. The shielded applicator designs investigated here, allow for reduction of the dose by over 50% at 5 mm from the applicator surface in desired regions, while also allowing radially symmetric dose with isodose line deviations less than 0.5 mm from circular. The shielding designs were also chosen with treatment delivery time in mind. Treatment times for these shielded designs were found to be less than 1.4 times longer than a 6-channel unshielded cylinder for the equivalent fully symmetric dose distribution. The 2D calculation methods developed here provide a simple way to rapidly evaluate shielding designs, while the 3D printing techniques also allow for devices with novel shapes to be rapidly prototyped. Both TOPAS Monte Carlo and Acuros BV calculations show that significant dose shaping and organ at risk sparing can be achieved without significantly compromising the plan in regions that require the full dose.Funding Information
- Stanford women cancer institute (LOI 2019)
This publication has 17 references indexed in Scilit:
- Systematic Review of Intensity-Modulated Brachytherapy (IMBT): Static and Dynamic TechniquesInternational Journal of Radiation Oncology*Biology*Physics, 2019
- Computed tomography–planned interstitial brachytherapy for locally advanced gynecologic cancer: Outcomes and dosimetric predictors of urinary toxicityBrachytherapy, 2015
- Regulatory Considerations in the Design and Manufacturing of Implantable 3D‐Printed Medical DevicesClinical and Translational Science, 2015
- Direction-Modulated Brachytherapy for High-Dose-Rate Treatment of Cervical Cancer. I: Theoretical DesignInternational Journal of Radiation Oncology*Biology*Physics, 2014
- TOPAS: An innovative proton Monte Carlo platform for research and clinical applicationsMedical Physics, 2012
- 3D Slicer as an image computing platform for the Quantitative Imaging NetworkMagnetic Resonance Imaging, 2012
- American Brachytherapy Society consensus guidelines for interstitial brachytherapy for vaginal cancerBrachytherapy, 2012
- Geant4—a simulation toolkitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- Monte Carlo dosimetry of a new high dose rate brachytherapy sourceMedical Physics, 2000
- A Monte Carlo investigation of the dosimetric characteristics of the VariSource 192Ir high dose rate brachytherapy sourceMedical Physics, 1999