Abstract
Diagnosis of COVID is performed by PCR methods, but their capacity is limited by the requirement of high-level facilities and instruments. The loop-mediated isothermal amplification (LAMP) method has been utilized for the detection of isolated virus-specific RNA. Preliminary data suggest the possibility of isothermal amplification directly from respiratory samples without RNA extraction. All patients admitted to our hospital were screened for SARS-CoV-2 by routine. Respiratory samples were tested by variplex system based on LAMP method directly without RNA extraction and by PCR. Primary endpoint was the false-negative rate of variplex test compared with PCR as gold standard. In 109 patients variplex test and PCR assay were performed simultaneously. Median age was 80 years and male/female ratio was 40/60%. The prevalence of PCR-confirmed COVID diagnosis was 43.1%. Variplex test was positive in 13.8%. False-negative rate of variplex test compared with PCR was 83.0%. The potential of LAMP technology using isolated RNA has been demonstrated impressively by others, and excellent sensitivity and specificity of detecting SARS-CoV-2 has been reported. However, without RNA extraction, the variplex test system failed to reliably detect SARS-CoV-2 directly in respiratory samples.Funding Information
- Technische Universität München
This publication has 19 references indexed in Scilit:
- Rapid and visual detection of 2019 novel coronavirus (SARS-CoV-2) by a reverse transcription loop-mediated isothermal amplification assayClinical Microbiology & Infection, 2020
- Coronavirus Disease 2019 (COVID-19): Protecting Hospitals From the InvisibleAnnals of Internal Medicine, 2020
- Clinical Characteristics of Coronavirus Disease 2019 in ChinaThe New England Journal of Medicine, 2020
- Development of Reverse Transcription Loop-Mediated Isothermal Amplification Assays Targeting Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2)The Journal of Molecular Diagnostics, 2020
- 2019 Novel Coronavirus Disease (COVID-19): Paving the Road for Rapid Detection and Point-of-Care DiagnosticsMicromachines, 2020
- Detection of SARS-CoV-2 in Different Types of Clinical SpecimensJAMA, 2020
- A Novel Coronavirus from Patients with Pneumonia in China, 2019The New England Journal of Medicine, 2020
- A new coronavirus associated with human respiratory disease in ChinaNature, 2020
- Clinical features of patients infected with 2019 novel coronavirus in Wuhan, ChinaThe Lancet, 2020
- Loop-mediated isothermal amplification (LAMP): principle, features, and future prospectsJournal of Microbiology, 2015