Abstaining from symptomatic implants of modified tension band wiring by nonabsorbable suture fixation for transverse patella fractures
Open Access
- 9 June 2021
- journal article
- research article
- Published by Springer Science and Business Media LLC in Journal of Orthopaedic Surgery and Research
- Vol. 16 (1), 1-9
- https://doi.org/10.1186/s13018-021-02494-3
Abstract
Background Modified tension band fixation has become commonly used for transverse patella fractures. The conventional stainless steel wire provides sufficient stability but may be associated with complications. Objective The study aimed to evaluate the effectiveness of a new modified tension band fixation technique for transverse patella fractures using a nonabsorbable suture. Material and methods We present the result of a prospective series using a nonabsorbable suture (FiberWire) for transverse patella fractures. The mean follow-up period totaled 12 months. A total of 16 patients were evaluated by radiographic and clinical review. The postoperative clinical evaluation employed Lysholm and Böstman scores. Result All clinical results on follow-up were good to excellent. Minimal intra-articular joint stepping and further fracture displacement were recorded. No patient needed re-operation, and functional outcomes of the knee were satisfactory. No significant differences were found between the injured and contralateral knee range of motion. No symptomatic implants and skin complications were noted, and all fractures were completed heal within 15 weeks. Conclusion FiberWire provided sufficient stability and reduced postoperative complications. The results proved appropriate, and the technique has merit, as it obviates the need for re-operation.This publication has 23 references indexed in Scilit:
- Treatment of transverse patellar fractures: a comparison between metallic and non-metallic implantsBritish Medical Bulletin, 2013
- Functional Outcomes After Operatively Treated Patella FracturesJournal of Orthopaedic Trauma, 2012
- Double fixation of displaced patella fractures using bioabsorbable cannulated lag screws and braided polyester suture tension bandsInjury, 2011
- Implant Removal Following Surgical Stabilization of Patella FractureOrthopedics, 2010
- Development of the Radiographic Union Score for Tibial Fractures for the Assessment of Tibial Fracture Healing After Intramedullary FixationThe Journal of Trauma and Acute Care Surgery, 2010
- FiberWire® is superior in strength to stainless steel wire for tension band fixation of transverse patellar fracturesInjury, 2009
- Variability in the Assessment of Fracture-Healing in Orthopaedic Trauma StudiesJournal of Bone and Joint Surgery, 2008
- Clinical experience of patellar fracture fixation using metal wire or non-absorbable polyester — a study of 37 casesInjury, 2001
- Evaluation of knee ligament surgery results with special emphasis on use of a scoring scaleThe American Journal of Sports Medicine, 1982
- Comminuted displaced fractures of the patellaInjury, 1981