Abstract
Calculation of effective orifice area (EOA) is crucial for the evaluation of prosthetic valve (PV) function and there is lack of data on the best method, particularly in obese patients, in whom two-dimensional (2D) transthoracic echocardiography (TTE) is cumbersome. We sought to compare two methods of calculating EOA through Continuity equation; one using standard 2D-TTE and other three-dimensional (3D) stoke volume (SV), in patients with bileaflet mechanical PV stratified by body mass index (BMI). On conventional TTE, SV mas measured using standard 2D derived data and 3D derived SV in 38 aortic and 62 mitral PV patients who were referred for further evaluation for mild/moderate symptoms of dyspnea. Patients were categorized with regard to transprosthetic flow into 'normal-flow' and 'high-flow' groups and several echocardiographic data including 2D and 3D EOA were compared. Rates of obesity (BMI >= 30) were similar within high and normal flow groups of mitral and aortic PV patients. Correlation and agreement of 2D and 3D EOA was sought in patients with and without obesity. After identifying patients with possible severe obstruction, ROC analysis was carried out to identify whether 2D and 3D derived EOA could discriminate those with obstruction. There was good correlation and agreement between two methods in patients without obesity in both mitral and aortic PV. In obese individuals, however, there was no correlation between 2D and 3D EOA; in whom echocardiographic criteria showing severe obstruction revealed that 3D EOA measurements were more accurate. ROC analysis supported that 3D EOA performs better to identify patients with obstructive characteristics. In patients with bileaflet PV, measurement of EAO by 3D derived SV yields more accurate results irrespective of BMI.Keywords
This publication has 28 references indexed in Scilit:
- Cardiovascular magnetic resonance evaluation of aortic stenosis severity using single plane measurement of effective orifice areaJournal of Cardiovascular Magnetic Resonance, 2012
- Multimodal Assessment of the Aortic Annulus Diameter: Implications for Transcatheter Aortic Valve ImplantationJournal of the American College of Cardiology, 2010
- Guidelines for the Evaluation of Prosthetic Valves with Echocardiography and Doppler Ultrasound: Value and LimitationsEchocardiography, 2010
- Recommendations for Evaluation of Prosthetic Valves With Echocardiography and Doppler Ultrasound: A Report From the American Society of Echocardiography's Guidelines and Standards Committee and the Task Force on Prosthetic Valves, Developed in Conjunction With the American College of Cardiology Cardiovascular Imaging Committee, Cardiac Imaging Committee of the American Heart Association, the European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography and the Canadian Society of Echocardiography, Endorsed by the American College of Cardiology Foundation, American Heart Association, European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography, and Canadian Society of EchocardiographyJournal of the American Society of Echocardiography, 2009
- Direct measurement of left ventricular outflow tract by transthoracic real-time 3D-echocardiography increases accuracy in assessment of aortic valve stenosisInternational Journal of Cardiology, 2009
- Real-time three-dimensional echocardiography in aortic stenosis: a novel, simple, and reliable method to improve accuracy in area calculationEuropean Heart Journal, 2007
- Characteristics and Impact of Obesity on the Outpatient Echocardiography LaboratoryThe American Journal of Cardiology, 2006
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Obesity and cardiac function.Circulation, 1981
- Measurement of stroke volume from pulmonary artery pressure record in man.Heart, 1975