Double Trouble: Patients With Both True and False Arrhythmia Alarms
- 1 April 2020
- journal article
- research article
- Published by AACN Publishing in Critical Care Nurse
- Vol. 40 (2), 14-23
- https://doi.org/10.4037/ccn2020363
Abstract
Patients with both true and false arrhythmia alarms pose a challenge because true alarms might be buried among a large number of false alarms, leading to missed true events. To determine (1) the frequency of patients with both true and false arrhythmia alarms; (2) patient, clinical, and electrocardiographic characteristics associated with both true and false alarms; and (3) the frequency and types of true and false arrhythmia alarms. This was a secondary analysis using data from an alarm study conducted at a tertiary academic medical center. Of 461 intensive care unit patients, 211 (46%) had no arrhythmia alarms, 12 (3%) had only true alarms, 167 (36%) had only false alarms, and 71 (15%) had both true and false alarms. Ventricular pacemaker, altered mental status, mechanical ventilation, and cardiac intensive care unit admission were present more often in patients with both true and false alarms than among other patients (P < .001). Intensive care unit stays were longer in patients with only false alarms (mean [SD], 106 [162] hours) and those with both true and false alarms (mean [SD], 208 [333] hours) than in other patients. Accelerated ventricular rhythm was the most common alarm type (37%). An awareness of factors associated with arrhythmia alarms might aid in developing solutions to decrease alarm fatigue. To improve detection of true alarms, further research is needed to build and test electrocardiographic algorithms that adjust for clinical and electrocardiographic characteristics associated with false alarms.Keywords
This publication has 32 references indexed in Scilit:
- Novel Approach to Cardiac Alarm Management on Telemetry UnitsJournal of Cardiovascular Nursing, 2014
- Use of Pagers With an Alarm Escalation System to Reduce Cardiac Monitor Alarm SignalsJournal of Nursing Care Quality, 2014
- Managing clinical alarmsNursing Management, 2013
- Pulse oximetry desaturation alarms on a general postoperative adult unit: A prospective observational study of nurse response timeInternational Journal of Nursing Studies, 2013
- What Are We Missing? Arrhythmia Detection in the Pediatric Intensive Care UnitThe Journal of Pediatrics, 2013
- Daily Electrode Change and Effect on Cardiac Monitor AlarmsJournal of Nursing Care Quality, 2013
- Monitor Alarm Fatigue : An Integrative ReviewBiomedical Instrumentation & Technology, 2012
- Reducing False Alarms of Intensive Care Online-Monitoring Systems: An Evaluation of Two Signal Extraction AlgorithmsComputational and Mathematical Methods in Medicine, 2011
- Monitor Alarm Fatigue: Standardizing Use of Physiological Monitors and Decreasing Nuisance AlarmsAmerican Journal of Critical Care, 2010
- Human probability matching behaviour in response to alarms of varying reliabilityErgonomics, 1995