Imaging plates are widely used in laser-plasma interaction experiments for detection of electrons, x-ray, gamma-ray, ions, and neutrons, therefore, the calibration of imaging plates to different types of ionizing and non-ionizing radiation is vital. In this paper, a universal response function of FUJI BAS-TR imaging plate is presented using experiment and Monte-Carlo simulation with respect to high-energy photons and ions. The sensitivity of imaging plate sensitivity to x-ray radiation was examined using radioactive Co-60 isotope. Furthermore, the fading and decay mechanism affected by phosphor stimulated process were also investigated by employing the high energy gamma-rays produced in laser-plasma experiment. Finally, an ion spectrometer was designed to examine the IP response to different ion energies during a laser-driven plasma experiment. The universal relation given, can be used to evaluate the response of the imaging plate against any other types of radiation.Keywords
This publication has 37 references indexed in Scilit:
- Bright Laser-Driven Neutron Source Based on the Relativistic Transparency of SolidsPhysical Review Letters, 2013
- Femtosecond x rays from laser-plasma acceleratorsReviews of Modern Physics, 2013
- Response functions of Fuji imaging plates to monoenergetic protons in the energy range 0.6–3.2 MeVReview of Scientific Instruments, 2013
- Multichannel film dosimetry with nonuniformity correctionMedical Physics, 2011
- Development of a high resolution and high dispersion Thomson parabolaReview of Scientific Instruments, 2011
- Absolute response of Fuji imaging plate detectors to picosecond-electron bunchesReview of Scientific Instruments, 2010
- Radiochromic film imaging spectroscopy of laser-accelerated proton beamsReview of Scientific Instruments, 2009
- Absolute calibration of photostimulable image plate detectors used as (0.5–20MeV) high-energy proton detectorsReview of Scientific Instruments, 2008
- Novel method for characterizing relativistic electron beams in a harsh laser-plasma environmentReview of Scientific Instruments, 2007
- Calibration of imaging plate for high energy electron spectrometerReview of Scientific Instruments, 2004