Introduction of a sEMG Sensor System for Autonomous Use by Inexperienced Users
Open Access
- 20 December 2020
- Vol. 20 (24), 7348
- https://doi.org/10.3390/s20247348
Abstract
Wearable devices play an increasing role in the rehabilitation of patients with movement disorders. Although information about muscular activation is highly interesting, no approach exists that allows reliable collection of this information when the sensor is applied autonomously by the patient. This paper aims to demonstrate the proof-of-principle of an innovative sEMG sensor system, which can be used intuitively by patients while detecting their muscular activation with sufficient accuracy. The sEMG sensor system utilizes a multichannel approach based on 16 sEMG leads arranged circularly around the limb. Its design enables a stable contact between the skin surface and the system’s dry electrodes, fulfills the SENIAM recommendations regarding the electrode size and inter-electrode distance and facilitates a high temporal resolution. The proof-of-principle was demonstrated by elbow flexion/extension movements of 10 subjects, proving that it has root mean square values and a signal-to-noise ratio comparable to commercial systems based on pre-gelled electrodes. Furthermore, it can be easily placed and removed by patients with reduced arm function and without detailed knowledge about the exact positioning of the sEMG electrodes. With its features, the demonstration of the sEMG sensor system’s proof-of-principle positions it as a wearable device that has the potential to monitor muscular activation in home and community settings.Funding Information
- Bundesministerium für Bildung, Wissenschaft und Forschung (FKZ: 13GW0122E and FKZ: 01DN18011A)
This publication has 45 references indexed in Scilit:
- A review of wearable sensors and systems with application in rehabilitationJournal of NeuroEngineering and Rehabilitation, 2012
- Inter-electrode spacing of surface EMG sensors: Reduction of crosstalk contamination during voluntary contractionsJournal of Biomechanics, 2012
- Technologies and combination therapies for enhancing movement training for people with a disabilityJournal of NeuroEngineering and Rehabilitation, 2012
- A Novel Approach to Ambulatory MonitoringNeurorehabilitation and Neural Repair, 2010
- Surface EMG: The issue of electrode locationJournal of Electromyography and Kinesiology, 2009
- Surface electromyography and muscle force: Limits in sEMG–force relationship and new approaches for applicationsClinical Biomechanics, 2009
- Technology and instrumentation for detection and conditioning of the surface electromyographic signal: State of the artClinical Biomechanics, 2009
- Effect of electrode location on EMG signal envelope in leg muscles during gaitJournal of Electromyography and Kinesiology, 2007
- Rehabilitation needs for older adults with stroke living at home: perceptions of four populationsBMC Geriatrics, 2007
- Validity of Accelerometry for Monitoring Real-World Arm Activity in Patients With Subacute Stroke: Evidence From the Extremity Constraint-Induced Therapy Evaluation TrialArchives of Physical Medicine and Rehabilitation, 2006