Abstract
(1) Background: The surveillance of SARS-CoV-2 RNA in urban wastewaters allows one to monitor the presence of the virus in a population, including asymptomatic and symptomatic individuals, capturing the real circulation of this pathogen. The aim of this study was to evaluate the performance of different pre-analytical and analytical methods for identifying the presence of SARS-CoV-2 in untreated municipal wastewaters samples by conducting an inter-laboratory proficiency test. (2) Methods: three methods of concentration, namely, (A) Dextran and PEG-6000 two-phase separation, (B) PEG-8000 precipitation without a chloroform purification step and (C) PEG-8000 precipitation with a chloroform purification step were combined with three different protocols of RNA extraction by using commercial kits and were tested by using two primers/probe sets in three different master mixes. (3) Results: PEG-8000 precipitation without chloroform treatment showed the best performance in the SARS-CoV-2 recovery; no major differences were observed among the protocol of RNA extraction and the one-step real-time RT-PCR master mix kits. The highest analytic sensitivity was observed by using primers/probe sets targeting the N1/N3 fragments of SARS-CoV-2. (4) Conclusions: PEG-8000 precipitation in combination with real-time RT-PCR targeting the N gene (two fragments) was the best performing workflow for the detection of SARS-CoV-2 RNA in municipal wastewaters.