Identification of critical chemical modifications and paratope mapping by size exclusion chromatography of stressed antibody-target complexes
Open Access
- 1 January 2021
- journal article
- research article
- Published by Informa UK Limited in mAbs
- Vol. 13 (1), 1887629
- https://doi.org/10.1080/19420862.2021.1887629
Abstract
Therapeutic proteins including antibodies and Fc-fusion proteins undergo a large number of chemical modifications during cell culture, purification, storage and in human circulation. They are also exposed to harsh conditions during stress studies, including elevated temperature, extremes of pH, forced oxidation, physiological pH, UV light to assess the possible degradation pathways and suitability of methods for detecting them. Some of these modifications are located on residues in binding regions, leading to loss of binding and potency and classified as critical quality attributes. Currently, criticality of modifications is assessed by a laborious process of collecting antibody fractions from the soft chromatography techniques ion exchange and hydrophobic interaction chromatography and characterizing the fractions one-by-one for potency and chemical modifications. Here, we describe a method for large-scale, parallel identification of all critical chemical modifications in one experiment. In the first step, the antibody is stressed by one or several stress methods. It is then mixed with target protein and separated by size-exclusion chromatography (SEC) on bound antibody-target complex and unbound antibody. Peptide mapping of fractions and statistical analysis are performed to identify modifications on amino acid residues that affect binding. To identify the modifications leading to slight decreases in binding, competitive SEC of antibody and antigen mixtures was developed and described in a companion study by Shi et al, where target protein is provided at lower level, below the stoichiometry. The newly described method was successfully correlated to crystallography for assessing criticality of chemical modifications and paratope mapping. It is more sensitive to low-level modifications, better streamlined and platform ready.Keywords
This publication has 47 references indexed in Scilit:
- Characterization of the basic charge variants of a human IgG1mAbs, 2011
- Fast Photochemical Oxidation of Proteins for Epitope MappingAnalytical Chemistry, 2011
- Post-translational Modifications Differentially Affect IgG1 Conformation and Receptor BindingMolecular & Cellular Proteomics, 2010
- Fast Photochemical Oxidation of Protein Footprints Faster than Protein UnfoldingAnalytical Chemistry, 2009
- Effect of Copper Sulfate on Performance of a Serum-Free CHO Cell Culture Process and the Level of Free Thiol in the Recombinant Antibody ExpressedBiotechnology Progress, 2008
- Hydrogen exchange and mass spectrometry: A historical perspectiveJournal of the American Society for Mass Spectrometry, 2006
- Nanosecond Laser-Induced Photochemical Oxidation Method for Protein Surface Mapping with Mass SpectrometryAnalytical Chemistry, 2005
- Radiolytic Modification of Acidic Amino Acid Residues in Peptides: Probes for Examining Protein−Protein InteractionsAnalytical Chemistry, 2004
- Overview of the Quantitation of Protein InteractionsCurrent Protocols in Protein Science, 1999
- Determination of amide hydrogen exchange by mass spectrometry: A new tool for protein structure elucidationProtein Science, 1993