Direct Conversion X-Ray Detectors with High Sensitivity at Low Dose Rate Based on All-Inorganic Lead-Free Perovskite Wafers

Cuixian Zhang
Published: 1 January 2022

Abstract: Just as lead-based perovskites that are hot in solar cell preparation, Bi-based perovskites have demonstrated excellent performance in direct X-ray detection, especially the Cs3Bi2I9 single crystals (SCs). However, compared with lead-halide perovskites, one challenge for the Cs3Bi2I9 SCs for X-ray detection application is that it is difficult to prepare large-sized and high-quality SCs. Therefore, how to get a large area with a high-quality wafer is also as important as Cs3Bi2I9 growth method research. Here, different anti-solvents are used for the preparation of poly-crystalline powder with the Antisolvents precipitation (A) method, as a control, High-energy ball milling (B) was also used to prepare poly-crystalline powders. The resultant two types of Cs3Bi2I9 wafer exhibit a micro-strain of 1.21 × 10-3, a resistivity of 5.13 × 108 Ω cm and a microstrain of 1.21 × 10-3, a resistivity of 2.21 × 109 Ω cm. As a result, an X-ray detector based on the high-quality Cs3Bi2I9 wafer exhibits excellent dose rate linearity, a sensitivity of 588 μC·Gyairs-1·cm-2 and a limit of detection (LoD) of 76 nGyair·s-1.
Keywords: X-Ray Detection / Sensitivity / Cs3Bi2I9

Scifeed alert for new publications

Never miss any articles matching your research from any publisher
  • Get alerts for new papers matching your research
  • Find out the new papers from selected authors
  • Updated daily for 49'000+ journals and 6000+ publishers
  • Define your Scifeed now

Share this article

Click here to see the statistics on "Detection" .
References (25)
    Back to Top Top