RETRACTED: Effect of Lowering Laser Energy on the Surface Roughness of Human Corneal Lenticules in SMILE
- 1 September 2017
- journal article
- retracted article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 33 (9), 617-624
- https://doi.org/10.3928/1081597x-20170620-02
Abstract
To determine the effect of lowering femtosecond laser energy on the surface quality of the intrastromal interface during small incision lenticule extraction (SMILE). Forty age- and diopter-matched female patients (40 eyes) with moderate myopia received SMILE with different energy levels (100 to 150 nJ) and fixed spot separation (4.5 μm). Five human corneal lenticules from each energy group were evaluated by atomic force microscopy and scanning electron microscopy (SEM). Both anterior and posterior surface characteristics of the lenticules were assessed. All measurements of surface roughness were approximately three times higher and in the anterior and posterior surface of the lenticules with the energy level of 150 nJ than with 100 nJ (P < .001). Furthermore, atomic force microscopy analysis found that energy differences of 15 nJ or more made a significant difference in surface roughness at energy levels of 115 nJ or higher. Interestingly, there was no significant difference in all roughness values of both surfaces among the 100, 105, and 110 nJ groups. In addition, all values of surface roughness were significantly positively correlated with laser energy for both anterior and posterior surfaces of the lenticule (P < .001). Consistent with atomic force microscopy results, SEM also showed that the SMILE lenticules in the higher laser energy group had more irregular surfaces. Lowering laser energy levels can improve surface quality of the lenticule of SMILE. To achieve better visual outcomes with faster recovery after the procedure, it is recommended to reduce the laser energy to less than 115 nJ at a spot separation of 4.5 μm. [J Refract Surg. 2017;33(9):617-624.].Keywords
This publication has 18 references indexed in Scilit:
- Clinical Outcomes of SMILE and FS-LASIK Used to Treat Myopia: A Meta-analysisJournal of Refractive Surgery, 2016
- Effect of femtosecond laser setting on visual performance after small-incision lenticule extraction for myopiaBritish Journal of Ophthalmology, 2015
- Small-incision lenticule extractionJournal of Cataract & Refractive Surgery, 2015
- Small incision lenticule extraction (SMILE) history, fundamentals of a new refractive surgery technique and clinical outcomesEye and Vision, 2014
- Corneal biomechanical effects: Small-incision lenticule extraction versus femtosecond laser–assisted laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2014
- Predictors for the Outcome of Small-incision Lenticule Extraction for MyopiaJournal of Refractive Surgery, 2012
- Small-incision lenticule extraction for moderate to high myopia: Predictability, safety, and patient satisfactionJournal of Cataract & Refractive Surgery, 2012
- Early clinical outcomes, including efficacy and endothelial cell loss, of refractive lenticule extraction using a 500 kHz femtosecond laser to correct myopiaJournal of Cataract & Refractive Surgery, 2012
- Femtosecond Lenticule Extraction (FLEx): Clinical Results, Interface Evaluation, and Intraocular Pressure VariationInvestigative Ophthalmology & Visual Science, 2012
- Effect of scanning patterns on the results of femtosecond laser lenticule extraction refractive surgeryJournal of Cataract & Refractive Surgery, 2011