Zn–0.8Mg–0.2Sr (wt.%) Absorbable Screws—An In-Vivo Biocompatibility and Degradation Pilot Study on a Rabbit Model
Open Access
- 13 June 2021
- Vol. 14 (12), 3271
- https://doi.org/10.3390/ma14123271
Abstract
In this pilot study, we investigated the biocompatibility and degradation rate of an extruded Zn–0.8Mg–0.2Sr (wt.%) alloy on a rabbit model. An alloy screw was implanted into one of the tibiae of New Zealand White rabbits. After 120 days, the animals were euthanized. Evaluation included clinical assessment, microCT, histological examination of implants, analyses of the adjacent bone, and assessment of zinc, magnesium, and strontium in vital organs (liver, kidneys, brain). The bone sections with the implanted screw were examined via scanning electron microscopy and energy dispersive spectroscopy (SEM-EDS). This method showed that the implant was covered by a thin layer of phosphate-based solid corrosion products with a thickness ranging between 4 and 5 µm. Only negligible changes of the implant volume and area were observed. The degradation was not connected with gas evolution. The screws were fibrointegrated, partially osseointegrated histologically. We observed no inflammatory reaction or bone resorption. Periosteal apposition and formation of new bone with a regular structure were frequently observed near the implant surface. The histological evaluation of the liver, kidneys, and brain showed no toxic changes. The levels of Zn, Mg, and Sr after 120 days in the liver, kidneys, and brain did not exceed the reference values for these elements. The alloy was safe, biocompatible, and well-tolerated.Funding Information
- Grantová Agentura České Republiky (18-06110S)
- Operational Program Research, Development and Education financed by European Structural and Investment Funds and the Czech Ministry of Education, Youth and Sports (SOLID21-CZ.02.1.01/0.0/0.0/16_019/0000760, LM2018110)
This publication has 57 references indexed in Scilit:
- Biodegradable magnesium-based screw clinically equivalent to titanium screw in hallux valgus surgery: short term results of the first prospective, randomized, controlled clinical pilot studyBioMedical Engineering OnLine, 2013
- In vitro and in vivo studies on a Mg-Sr binary alloy system developed as a new kind of biodegradable metalActa Biomaterialia, 2012
- Magnesium alloys for temporary implants in osteosynthesis: In vivo studies of their degradation and interaction with boneActa Biomaterialia, 2012
- Effect of Magnesium Supplementation on the Distribution Patterns of Zinc, Copper, and Magnesium in Rabbits Exposed to Prolonged Cadmium IntoxicationThe Scientific World Journal, 2012
- Mechanical and corrosion properties of newly developed biodegradable Zn-based alloys for bone fixationActa Biomaterialia, 2011
- Design strategy for biodegradable Fe-based alloys for medical applicationsActa Biomaterialia, 2010
- Zinc may increase bone formation through stimulating cell proliferation, alkaline phosphatase activity and collagen synthesis in osteoblastic MC3T3-E1 cellsNutrition Research and Practice, 2010
- Methods for behavioral testing of spinal cord injured ratsNeuroscience & Biobehavioral Reviews, 2008
- Foreign body reaction to biomaterialsSeminars in Immunology, 2008
- Incidence and Economic Burden of Osteoporosis-Related Fractures in the United States, 2005–2025Journal of Bone and Mineral Research, 2007