Effect of shear stirrup space on short link beam of eccentric braced frame (EBF) V-type under cyclic loading
- 1 January 2021
- conference paper
- conference paper
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2447 (1), 030008
- https://doi.org/10.1063/5.0072627
Abstract
Some previous research indicated that a short link beam in an Eccentric Braced Frame (EBF) yields due to shear rather than flexure. Stirrups inside a concrete beam structure are functioned to carry shear forces beside concrete material itself. It means that the effect of spacing between shear stirrups is a very important aspect in increasing a short link beam structural capacity. Present study used EBF with brace V-type (EBF-V) due to its good performance compared to diagonal and inverted-V. Seven reinforced concrete braced frame structures consist of one EBF-V with short link stirrup space of 150 mm, three EBF-V with short link stirrup space of 75 mm and three Concentric Braced Frame V-type (CBF-V) as control models. Under cyclic loading conditions, load-displacement relationship and crack positions were observed. Results indicated that CBF-V models have the highest maximum load. On the other hand, EBF-V has a larger displacement than CBF-V. Smaller stirrup space results in a slightly higher strength but lower ductility. Crack visualizations of CBF-V and EBF-V model are also presented.Keywords
This publication has 9 references indexed in Scilit:
- COMPARISON STUDY OF BRACING CONFIGURATION WITH SHEAR LINK IN ECCENTRICALLY BRACED FRAME STEEL STRUCTUREJournal Innovation of Civil Engineering (JICE), 2020
- Study on the behavior of a one way eccentric braced frame under lateral loadAsian Journal of Civil Engineering, 2020
- Experimentally and analytically study on eccentrically braced frame with vertical shear linksThe Structural Design of Tall and Special Buildings, 2019
- A Review of Influence of Various Types of Structural Bracing to the Structural Performance of BuildingsE3S Web of Conferences, 2018
- Investigating the nonlinear behavior of Eccentrically Braced Frame with vertical shear links (V-EBF)Journal of Building Engineering, 2017
- An analytical model for inelastic cyclic response of eccentrically braced frame with vertical shear link (V-EBF)Case Studies in Structural Engineering, 2016
- EFFECT OF LINK ON ECCENTRICALLY BRACED FRAMESJES. Journal of Engineering Sciences, 2012
- Reduced Link Sections for Improving the Ductility of Eccentrically Braced Frame Link-to-Column ConnectionsJournal of Structural Engineering, 2010
- Experimental Investigation on Shear Cracking Behavior in Reinforced Concrete Beams with Shear ReinforcementJournal of Advanced Concrete Technology, 2009