Measuring synchrony in bio-medical timeseries
- 1 January 2021
- journal article
- research article
- Published by AIP Publishing in Chaos: An Interdisciplinary Journal of Nonlinear Science
- Vol. 31 (1), 013138
- https://doi.org/10.1063/5.0026733
Abstract
Paroxysms are sudden, unpredictable, short-lived events that abound in physiological processes and pathological disorders, from cellular functions (e.g., hormone secretion and neuronal firing) to life-threatening attacks (e.g., cardiac arrhythmia, epileptic seizures, and diabetic ketoacidosis). With the increasing use of personal chronic monitoring (e.g., electrocardiography, electroencephalography, and glucose monitors), the discovery of cycles in health and disease, and the emerging possibility of forecasting paroxysms, the need for suitable methods to evaluate synchrony—or phase-clustering—between events and related underlying physiological fluctuations is pressing. Here, based on examples in epilepsy, where seizures occur preferentially in certain brain states, we characterize different methods that evaluate synchrony in a controlled timeseries simulation framework. First, we compare two methods for extracting the phase of event occurrence and deriving the phase-locking value, a measure of synchrony: (M1) fitting cycles of fixed period-length vs (M2) deriving continuous cycles from a biomarker. In our simulations, M2 provides stronger evidence for cycles. Second, by systematically testing the sensitivity of both methods to non-stationarity in the underlying cycle, we show that M2 is more robust. Third, we characterize errors in circular statistics applied to timeseries with different degrees of temporal clustering and tested with different strategies: Rayleigh test, Poisson simulations, and surrogate timeseries. Using epilepsy data from 21 human subjects, we show the superiority of testing against surrogate time-series to minimize false positives and false negatives, especially when used in combination with M1. In conclusion, we show that only time frequency analysis of continuous recordings of a related bio-marker reveals the full extent of cyclical behavior in events. Identifying and forecasting cycles in biomedical timeseries will benefit from recordings using emerging wearable and implantable devices, so long as conclusions are based on conservative statistical testing.Keywords
This publication has 31 references indexed in Scilit:
- The Cardiomyocyte Circadian ClockCirculation Research, 2010
- Do Interictal Spikes Sustain Seizures and Epileptogenesis?Epilepsy Currents, 2006
- Interictal Spikes and EpileptogenesisEpilepsy Currents, 2006
- Theta-Modulated Place-by-Direction Cells in the Hippocampal Formation in the RatJournal of Neuroscience, 2004
- A review of wavelets in biomedical applicationsProceedings of the IEEE, 1996
- Fast wavelet transformation of EEGElectroencephalography and Clinical Neurophysiology, 1994
- Circadian variation in the frequency of sudden cardiac death.Circulation, 1987
- Electroencephalographic spiking activity, drug levels, and seizure occurence in epileptic patientsAnnals of Neurology, 1985
- RHYTHM IN EPILEPSYThe Lancet, 1938
- TIME OF DAY IN RELATION TO CONVULSIONS IN EPILEPSY.The Lancet, 1929