High-Frame Rate Vector Flow Imaging Technique: Initial Application in Evaluating the Hemodynamic Changes of Carotid Stenosis Caused by Atherosclerosis
Open Access
- 8 March 2021
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
Abstract
Objective: To investigate the value of high-frame rate vector flow imaging technique (V flow) in evaluating the hemodynamic changes of carotid stenosis caused by atherosclerotic plaques. Methods and Materials: In this prospective study, patients with stenosis rate (diameter) ≥30% caused by carotid atherosclerotic plaques were included. Degrees of carotid stenosis were graded according to North American Symptomatic Carotid Endarterectomy Trial criteria: moderate (30–69%) or severe (70–99%). Mindray Resona 7s ultrasound machine with a linear array transducer (3–11 MHz) was used for ultrasound examinations. The mean WSS value of carotid arteries was measured at the proximal, narrowest region and distal of carotid stenosis. The mean WSS values were correlated with peak systolic velocity (PSV) measured by color Doppler flow imaging and stenosis degree detected by digital subtraction angiography (DSA). The vector arrows and flow streamline detected by V flow dynamic imaging were analyzed. Imaging findings of DSA in carotid arteries were used as the gold standard. Results: Finally, 51 patients were included. V flow measurements were performed successfully in 17 patients (100%) with moderate-grade stenosis and in 30 patients (88.2%) with severe-grade stenosis. Dynamic V flow imaging showed yellow or red vectors at the stenotic segment, indicating fast speed blood flow (up to 260.92 cm/s). Changes of streamlines were detected in the stenotic segment. The mean WSS value measured at the narrowest region of the carotid artery had a moderately positive correlation with stenosis degree (r = 0.58, P < 0.05) and PSV value (r = 0.54, P < 0.05), respectively. Significant difference was detected in mean WSS value at the narrowest region of the carotid artery between severe carotid stenosis (1.47 ± 0.97 Pa) and moderate carotid stenosis (0.96 ± 0.44 Pa) (P < 0.05). Conclusion: The hemodynamic changes detected by V flow of the carotid stenosis might be a potential non-invasive imaging tool for assessing the degree of carotid stenosis.Keywords
This publication has 29 references indexed in Scilit:
- Imaging modalities to diagnose carotid artery stenosis: progress and prospectBioMedical Engineering OnLine, 2019
- The role of wall shear stress in the parent artery as an independent variable in the formation status of anterior communicating artery aneurysmsEuropean Radiology, 2018
- High wall shear stress and high-risk plaque: an emerging conceptThe International Journal of Cardiovascular Imaging, 2017
- Relationship Between Carotid Stenosis and Infarct Volume in Ischemic Stroke PatientsMedical Science Monitor, 2016
- Association of Wall Shear Stress with Coronary Plaque Progression and TransformationInterventional Cardiology Clinics, 2015
- Quantitative Analysis of Wall Shear Stress for Human Carotid Bifurcation at Cardiac Phases by the Use of Phase Contrast Cine Magnetic Resonance Imaging: Computational Fluid Dynamics StudyJapanese Journal of Radiological Technology, 2015
- The Diagnosis, Treatment and Follow-up of Extracranial Carotid StenosisDeutsches Ärzteblatt international, 2013
- Carotid Artery Stenosis: Accuracy of Noninvasive Tests—Individual Patient Data Meta-AnalysisRadiology, 2009
- The role of shear stress in the generation of rupture-prone vulnerable plaquesNature Clinical Practice Cardiovascular Medicine, 2005
- Hemodynamic Shear Stress and Its Role in AtherosclerosisJAMA, 1999