Comparison of Enhancement of the Vestibular Perilymph between Variable and Constant Flip Angle–Delayed 3D-FLAIR Sequences in Menière Disease
- 19 March 2020
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 41 (4), 706-711
- https://doi.org/10.3174/ajnr.a6483
Abstract
BACKGROUND AND PURPOSE: Endolymphatic hydrops in patients with Menière disease relies on delayed postcontrast 3D-FLAIR sequences. The purpose of this study was to compare the degree of perilymphatic enhancement and the detection rate of endolymphatic hydrops using constant and variable flip angles sequences. MATERIALS AND METHODS: This was a retrospective study performed in 16 patients with Menière disease who underwent 3T MR imaging 4 hours after gadolinium injection using two 3D-FLAIR sequences with a constant flip angle at 140° for the first and a heavily-T2 variable flip angle for the second. The signal intensity ratio was measured using the ROI method. We graded endolymphatic hydrops and evaluated the cochlear blood-labyrinth barrier impairment. RESULTS: Both for symptomatic and asymptomatic ears, the median signal intensity ratio was significantly higher with the constant flip angle than with the heavily-T2 variable flip angle (7.16 versus 1.54 and 7.00 versus 1.45, P < .001). Cochlear blood-labyrinth barrier impairment was observed in 4/18 symptomatic ears with the heavily-T2 variable flip angle versus 8/19 with constant flip angle sequences. With heavily-T2 variable flip angle sequences, endolymphatic hydrops was observed in 7–10/19 symptomatic ears versus 12/19 ears with constant flip angle sequences. We found a significant association between the clinical symptomatology and the presence of endolymphatic hydrops with constant flip angle but not with heavily-T2 variable flip angle sequences. Interreader agreement was always perfect with constant flip angle sequences while it was fair-to-moderate with heavily-T2 variable flip angle sequences. CONCLUSIONS: 3D-FLAIR constant flip angle sequences provide a higher signal intensity ratio and are superior to heavily-T2 variable flip angle sequences in reliably evaluating the cochlear blood-labyrinth barrier impairment and the endolymphatic space.Keywords
This publication has 30 references indexed in Scilit:
- Comprehensive comparison of MR image quality between intratympanic and intravenous gadolinium injection using 3D real IR sequencesActa Oto-Laryngologica, 2019
- The value of four stage vestibular hydrops grading and asymmetric perilymphatic enhancement in the diagnosis of Menière’s disease on MRINeuroradiology, 2019
- MRI of endolymphatic hydrops in patients with Meniere’s disease: a case-controlled study with a simplified classification based on saccular morphologyEuropean Radiology, 2016
- The Technical and Clinical Features of 3D-FLAIR in NeuroimagingMagnetic Resonance in Medical Sciences, 2015
- Imaging of M^|^eacute;ni^|^egrave;re's Disease after Intravenous Administration of Single-dose Gadodiamide: Utility of Subtraction Images with Different Inversion TimeMagnetic Resonance in Medical Sciences, 2012
- Comparison of Contrast Effect on the Cochlear Perilymph after Intratympanic and Intravenous Gadolinium InjectionAmerican Journal of Neuroradiology, 2011
- Endolymphatic hydrops and blood–labyrinth barrier in Ménière's diseaseActa Oto-Laryngologica, 2010
- Visualization of Endolymphatic Hydrops in Ménière's Disease with Single-dose Intravenous Gadolinium-based Contrast Media using Heavily T2-weighted 3D-FLAIRMagnetic Resonance in Medical Sciences, 2010
- Grading of endolymphatic hydrops using magnetic resonance imagingActa Oto-Laryngologica, 2009
- Observation of contrast enhancement in the cochlear fluid space of healthy subjects using a 3D-FLAIR sequence at 3 TeslaEuropean Radiology, 2005