Potential Usefulness of Tracking Head Movement via a Wearable Device for Equilibrium Function Testing at Home
Open Access
- 11 October 2022
- journal article
- research article
- Published by Springer Science and Business Media LLC in Journal of Medical Systems
- Vol. 46 (11), 1-9
- https://doi.org/10.1007/s10916-022-01874-4
Abstract
Many studies have reported the use of wearable devices to acquire biological data for the diagnosis and treatment of various diseases. Balance dysfunction, however, is difficult to evaluate in real time because the equilibrium function is conventionally examined using a stabilometer installed on the ground. Here, we used a wearable accelerometer that measures head motion to evaluate balance and examined whether it performs comparably to a conventional stabilometer. We constructed a simplified physical head-feet model that simultaneously records “head” motion measured using an attached wearable accelerometer and center-of-gravity motion at the “feet”, which is measured using an attached stabilometer. Total trajectory length (r = 0.818, p -false discovery rate [FDR] = 0.004) and outer peripheral area (r = 0.691, p -FDR = 0.026) values measured using the wearable device and stabilometer were significantly positively correlated. Root mean square area values were not significantly correlated with wearable device stabilometry but were comparable. These results indicate that wearable, widely available, non-medical devices may be used to assess balance outside the hospital setting, and new approaches for testing balance function should be considered.Keywords
This publication has 29 references indexed in Scilit:
- Use of Mobile Device Accelerometry to Enhance Evaluation of Postural Instability in Parkinson DiseaseArchives of Physical Medicine and Rehabilitation, 2016
- What is Menière’s disease? A contemporary re-evaluation of endolymphatic hydropsZeitschrift für Neurologie, 2016
- Vertigo and Dizziness in the ElderlyFrontiers in Neurology, 2015
- Clinical stabilometry standardization: Basic definitions – Acquisition interval – Sampling frequencyGait & Posture, 2013
- Sit-stand and stand-sit transitions in older adults and patients with Parkinson’s disease: event detection based on motion sensors versus force platesJournal of NeuroEngineering and Rehabilitation, 2012
- ISway: a sensitive, valid and reliable measure of postural controlJournal of NeuroEngineering and Rehabilitation, 2012
- Balance and gait problems in the elderlyHandbook of Clinical Neurology, 2012
- Development and Validation of a Digital Head Posture Measuring SystemAmerican Journal of Ophthalmology, 2009
- Criteria for evaluation of measurement properties of clinical balance measures for use in fall prevention studiesJournal of Evaluation in Clinical Practice, 2008
- Epidemiology of vertigoCurrent Opinion in Neurology, 2007