The Next Generation of IR Spectroscopy: EC-QCL-Based Mid-IR Transmission Spectroscopy of Proteins with Balanced Detection
Open Access
- 21 July 2020
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (14), 9901-9907
- https://doi.org/10.1021/acs.analchem.0c01406
Abstract
We report a mid-IR transmission setup for the analysis of the protein amide I and amide II band in aqueous solutions that achieves a limit of detection as low as 0.0025 mg mL(-)(1) (outperforming our previous results and other state-of-the-art mid-IR-based techniques by almost an order of magnitude). This large improvement is made possible by combining the latest-generation external cavity-quantum cascade laser (EC-QCL) operated at room temperature with an optimized double-beam optical setup that adjusts the path length (26 mu m) to ensure robust sample handling. For minimizing the noise introduced by the high-intensity laser light source, a thermoelectrically cooled mercury cadmium telluride balanced detection module was employed. In this way, noise levels better by a factor of up to 20 were achieved compared with single-channel measurements. Characteristic spectral features of proteins with different secondary structures were successfully identified at concentrations as low as 0.1 mg mL(-1). Furthermore, a highly linear response was demonstrated for concentrations between 0.05 and 10 mg mL(-1). The total acquisition time of the setup can be adapted to fulfill the required sensitivity of the protein measurements and to ensure maximum flexibility for future applications. The presented setup combines high sensitivity, large optical path lengths, and short measurement times and thus outperforms previous research type EC-QCL setups as well as commercially available instruments. This opens a wide range of future applications including protein-ligand interaction studies as well as qualitative and quantitative analyses of proteins in complex matrices such as those found in up- and downstream bioprocess monitoring and similar challenging applications which can not be readily met by conventional FT-IR spectroscopy.Funding Information
- Austrian Science Fund (P32644-N)
- Horizon 2020 Framework Programme (818110)
This publication has 40 references indexed in Scilit:
- Model Optimization and Stability of Hemoglobin Analysis in Human Soluble Blood Samples by FTIR/ATR SpectroscopyApplied Mechanics and Materials, 2011
- Application of multivariate curve resolution-alternating least squares (MCR-ALS) for secondary structure resolving of proteinsBiochimie, 2009
- Second-order advantage from kinetic-spectroscopic data matrices in the presence of extreme spectral overlapping: A multivariate curve resolution—Alternating least-squares approachAnalytica Chimica Acta, 2008
- Infrared spectroscopy of proteinsBiochimica et Biophysica Acta (BBA) - Bioenergetics, 2007
- Chemometric tools for classification and elucidation of protein secondary structure from infrared and circular dichroism spectroscopic measurementsProteins-Structure Function and Bioinformatics, 2006
- Basic Aspects of the Technique and Applications of Infrared Spectroscopy of Peptides and ProteinsPublished by American Chemical Society (ACS) ,1999
- Quantum Cascade LaserScience, 1994
- The solution structure of concanavalin A probed by FT-IR spectroscopyBiochimica et Biophysica Acta (BBA) - Protein Structure and Molecular Enzymology, 1988
- Conformational changes in concanavalin A associated with demetallization and α-methylmannose binding studied by Fourier transform infrared spectroscopyBiochimica et Biophysica Acta (BBA) - Protein Structure and Molecular Enzymology, 1987
- Automatic identification of secondary structure in globular proteinsJournal of Molecular Biology, 1977