Application of Adaptive Image Receive Coil Technology for Whole-Brain Imaging
- 1 February 2021
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 216 (2), 552-559
- https://doi.org/10.2214/ajr.20.22812
Abstract
OBJECTIVE. The Adaptive Image Receive (AIR) radiofrequency coil is an emergent technology that is lightweight and flexible and exhibits electrical characteristics that overcome many of the limitations of traditional rigid coil designs. The purpose of this study was to apply the AIR coil for whole-brain imaging and compare the performance of a prototype AIR coil array with the performance of conventional head coils. SUBJECTS AND METHODS. A phantom and 15 healthy adult participants were imaged. A prototype 16-channel head AIR coil was compared with conventional 8-and 32-channel head coils using clinically available MRI sequences. During consensus review, two board-certified neuroradiologists graded the AIR coil compared with an 8-channel coil and a 32-channel coil on a 5-point ordinal scale in multiple categories. One- and two-sided Wilcoxon signed rank tests were performed. Noise covariance matrices and geometry factor (g-factor) maps were calculated. RESULTS. The signal-to-noise ratio, structural sharpness, and overall image quality scores of the prototype 16-channel AIR coil were better than those of the 8-channel coil but were not as good as those of the 32-channel coil. Noise covariance matrices showed stable performance of the AIR coil across participants. The median g-factors for the 16-channel AIR coil were, overall, less than those of the 8-channel coil but were greater than those of the 32-channel coil. CONCLUSION. On average, the prototype 16-channel head AIR coil outperformed a conventional 8-channel head coil but did not perform as well as a conventional 32-channel head coil. This study shows the feasibility of the novel AIR coil technology for imaging the brain and provides insight for future coil design improvements.Keywords
This publication has 17 references indexed in Scilit:
- Screen-printed flexible MRI receive coilsNature Communications, 2016
- High slew‐rate head‐only gradient for improving distortion in echo planar imaging: Preliminary experienceJournal of Magnetic Resonance Imaging, 2016
- Technical Note: Compact three‐tesla magnetic resonance imager with high‐performance gradients passes ACR image quality and acoustic noise testsMedical Physics, 2016
- Mechanically adjustable coil array for wrist MRIMagnetic Resonance in Medicine, 2009
- Comprehensive quantification of signal‐to‐noise ratio and g‐factor for image‐based and k‐space‐based parallel imaging reconstructionsMagnetic Resonance in Medicine, 2008
- An introduction to coil array design for parallel MRINMR in Biomedicine, 2006
- Advances in sensitivity encoding with arbitrary k‐space trajectoriesMagnetic Resonance in Medicine, 2001
- SENSE: sensitivity encoding for fast MRI.1999
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- The NMR phased arrayMagnetic Resonance in Medicine, 1990