Optimization of Adsorption and Desorption Time in the Extraction of Volatile Compounds in Brewed Java Arabica Coffee Using the HS-SPME/GC-MS Technique
Open Access
- 26 February 2022
- journal article
- Published by Institute of Research and Community Services Diponegoro University (LPPM UNDIP) in Jurnal Kimia Sains dan Aplikasi
- Vol. 25 (2), 49-55
- https://doi.org/10.14710/jksa.25.2.49-55
Abstract
The headspace solid phase microextraction (HS-SPME) technique has been recognized as a reliable technique for characterizing the aroma profile of Arabica coffee beans. The amount and content of the detected volatile compounds depend on the volatile analyte extraction process with HS-SPME, namely the adsorption and desorption processes. However, the optimal extraction time in applying coffee volatile compounds is still limited. This research aimed to obtain the optimum adsorption and desorption time in analyzing volatile compounds in brewed Java Arabica coffee. The adsorption time was optimized for 20 to 60 minutes with 5 minutes desorption time. The desorption time was optimized from 5 to 45 minutes with a 20 minutes of adsorption time. There are 14 volatile compounds with a peak area percentage of more than 2% from adsorption and desorption optimization. The optimal adsorption time was 50 minutes, where there were 5 of 7 compounds with the most significant area, such as 2-furfural (29%), 2-acetyl furan (3%), 2-furfuryl acetate (6%), 5-methyl furfural (12%), and 2-furfuryl alcohol (14%). Meanwhile, the most optimal desorption time was 5 minutes which detected 12 compounds, while the other desorption time only detected eight compounds. Furfuryl formate (2%), pyridine (12%), and 2-furfuryl alcohol (14%) had a higher peak area than the other compounds at a desorption time of 5 minutes. The results showed the same number of volatile compounds at each adsorption time. In conclusion, the adsorption time did not affect the number of compounds detected as in the optimization of desorption time. Adsorption and desorption time is crucial in analyzing volatile compounds from coffee using the HS-SPME/GC-MS technique.Keywords
Funding Information
- Direktorat Riset Dan Pengabdian Kepada Masyarakat
This publication has 17 references indexed in Scilit:
- Determination of volatile marker compounds of common coffee roast defectsFood Chemistry, 2016
- Coffea arabica instant coffee—Chemical view and immunomodulating propertiesCarbohydrate Polymers, 2014
- Successive advanced oxidation of pyridine by ultrasonic irradiation: effect of additives and kinetic studyDesalination and Water Treatment, 2013
- Prediction models for Arabica coffee beverage quality based on aroma analyses and chemometricsTalanta, 2012
- Optimization of the HS-SPME technique by using response surface methodology for evaluating chlorine disinfection by-products by GC in drinking waterJournal of the Brazilian Chemical Society, 2011
- Simultaneous optimization of the microextraction of coffee volatiles using response surface methodology and principal component analysisChemometrics and Intelligent Laboratory Systems, 2010
- Extraction Techniques for the Analysis of Virgin Olive Oil AromaPublished by Elsevier BV ,2010
- Reliable characterization of coffee bean aroma profiles by automated headspace solid phase microextraction‐gas chromatography‐mass spectrometry with the support of a dual‐filter mass spectra libraryJournal of Separation Science, 2005
- Optimizing Headspace Temperature and Time Sampling for Identification of Volatile Compounds in Ground Roasted Arabica CoffeeJournal of Agricultural and Food Chemistry, 2001
- Coupling of SPME and GC-AED for the Determination of Organometallic CompoundsMicrochimica Acta, 2000