Augmented deep learning model for improved quantitative accuracy of MR-based PET attenuation correction in PSMA PET-MRI prostate imaging
- 11 May 2020
- journal article
- research article
- Published by Springer Science and Business Media LLC in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 48 (1), 9-20
- https://doi.org/10.1007/s00259-020-04816-9
Abstract
Purpose Estimation of accurate attenuation maps for whole-body positron emission tomography (PET) imaging in simultaneous PET-MRI systems is a challenging problem as it affects the quantitative nature of the modality. In this study, we aimed to improve the accuracy of estimated attenuation maps from MRI Dixon contrast images by training an augmented generative adversarial network (GANs) in a supervised manner. We augmented the GANs by perturbing the non-linear deformation field during image registration between MRI and the ground truth CT images. Methods We acquired the CT and the corresponding PET-MR images for a cohort of 28 prostate cancer patients. Data from 18 patients (2160 slices and later augmented to 270,000 slices) was used for training the GANs and others for validation. We calculated the error in bone and soft tissue regions for the AC μ-maps and the reconstructed PET images. Results For quantitative analysis, we use the average relative absolute errors and validate the proposed technique on 10 patients. The DL-based MR methods generated the pseudo-CT AC μ-maps with an accuracy of 4.5% more than standard MR-based techniques. Particularly, the proposed method demonstrates improved accuracy in the pelvic regions without affecting the uptake values. The lowest error of the AC μ-map in the pelvic region was 1.9% for μ-mapGAN + aug compared with 6.4% for μ-mapdixon, 5.9% for μ-mapdixon + bone, 2.1% for μ-mapU-Net and 2.0% for μ-mapU-Net + aug. For the reconstructed PET images, the lowest error was 2.2% for PETGAN + aug compared with 10.3% for PETdixon, 8.7% for PETdixon + bone, 2.6% for PETU-Net and 2.4% for PETU-Net + aug.. Conclusion The proposed technique to augment the training datasets for training of the GAN results in improved accuracy of the estimated μ-map and consequently the PET quantification compared to the state of the art.Keywords
Funding Information
- Australian Research Council (LP170100494)
- Australian Research Council of Excellence for Integrative Brain Function (CE140100007)
- Reignwood Cultural Foundation (Reignwood Cultural Foundation)
This publication has 40 references indexed in Scilit:
- Evaluation of Atlas-Based Attenuation Correction for Integrated PET/MR in Human Brain: Application of a Head Atlas and Comparison to True CT-Based Attenuation CorrectionJournal of Nuclear Medicine, 2015
- PET-MRI: a review of challenges and solutions in the development of integrated multimodality imagingPhysics in Medicine & Biology, 2015
- An SPM8-Based Approach for Attenuation Correction Combining Segmentation and Nonrigid Template Formation: Application to Simultaneous PET/MR Brain ImagingJournal of Nuclear Medicine, 2014
- The multi-modal Australian ScienceS Imaging and Visualization Environment (MASSIVE) high performance computing infrastructure: applications in neuroscience and neuroinformatics researchFrontiers in Neuroscience, 2014
- PET/MR: a paradigm shiftCancer Imaging, 2013
- MRI-Based Attenuation Correction for Whole-Body PET/MRI: Quantitative Evaluation of Segmentation- and Atlas-Based MethodsJournal of Nuclear Medicine, 2011
- Positron Emission Tomography-Computed Tomography Standardized Uptake Values in Clinical Practice and Assessing Response to TherapySeminars in Ultrasound, CT and MRI, 2010
- Towards quantitative PET/MRI: a review of MR-based attenuation correction techniquesEuropean Journal of Nuclear Medicine and Molecular Imaging, 2008
- Method for transforming CT images for attenuation correction in PET/CT imagingMedical Physics, 2006
- Whole-body MRI at high field: technical limits and clinical potentialEuropean Radiology, 2005