Self-Identification of Cable-Driven Exoskeleton Based on Asynchronous Iterative Method
- 13 October 2021
- journal article
- research article
- Published by ASME International in Journal of Mechanisms and Robotics
- Vol. 14 (2), 1-25
- https://doi.org/10.1115/1.4052380
Abstract
The upper limb rehabilitation exoskeleton with cable-driven parallel structure has the advantages of light weight and large payload, etc. However, due to the non-rigid nature of the actuating cables and the different body shape of the wearer, the geometric parameters of the exoskeleton have a large error. The parameter identification of cable-driven exoskeleton is of great significance. An asynchronous self-identification method for the upper limb 7-DOF (Degree of freedom) cable-driven exoskeleton was proposed and used in a wearable multi-redundant exoskeleton. Asynchronous iteration eliminates the accumulation of joint errors. High identification reliability is achieved by selecting proper identification parameters and optimizing error model.With the method, the geometric parameters of the exoskeleton can be identified by using exoskeleton joint Angle and cable length data. The experiment verifies that the success rate of parameter identification for different wearers is in line with expectations, and the control precision and stability of the prototype are greatly improved after parameter identification.Keywords
Funding Information
- National Natural Science Foundation of China (51675018, 51975002)
This publication has 27 references indexed in Scilit:
- Certified Calibration of a Cable-Driven Robot Using Interval Contractor ProgrammingPublished by Springer Science and Business Media LLC ,2013
- Self-feedback motion control for cable-driven parallel manipulatorsProceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science, 2013
- Auto Calibration Method for Cable-Driven Parallel Robots Using Force SensorsPublished by Springer Science and Business Media LLC ,2012
- A unified local convergence analysis of inexact constrained Levenberg–Marquardt methodsOptimization Letters, 2011
- Kinematic calibration of a wire-actuated parallel robotMechanism and Machine Theory, 2007
- MIME robotic device for upper-limb neurorehabilitation in subacute stroke subjects: A follow-up studyJournal of Rehabilitation Research and Development, 2006
- Kinematic Calibration and Pose Measurement of a Medical Parallel Manipulator by Optical Position SensorsJournal of Robotic Systems, 2003
- Robot calibration by mobile camera systemsJournal of Robotic Systems, 1994
- Determination of Optimal Measurement Configurations for Robot Calibration Based on Observability MeasureThe International Journal of Robotics Research, 1991
- Identification and Observability Measure of a Basis Set of Error Parameters in Robot CalibrationJournal of Mechanical Design, 1989