Inter- and Intra-Rater Reliability of Individual Cerebral Blood Flow Measured by Quantitative Vessel-Flow Phase-Contrast MRI
Open Access
- 25 September 2020
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (10), 3099
- https://doi.org/10.3390/jcm9103099
Abstract
Vessel flow quantification by two-dimensional (2D) phase-contrast magnetic resonance imaging (PC-MRI) using a three-dimensional (3D) magnetic resonance angiography (MRA) model to measure cerebral blood flow has unclear analytical reliability. The present study aimed to determine the inter- and intra-rater reliability of quantitative vessel-flow PC-MRI and potential factors influencing its consistency. We prospectively recruited 30 Asian participants (aged 20–90 years; 16 women; 22 healthy and 8 stroke patients) for performing 1.5-T MR equipped with a head coil. Each participant was first scanned for time-of-flight magnetic resonance angiography (TOF-MRA) images for localization of intracranial arteries. The 2D PC-MRI for each cerebral artery (total 13 arteries in fixed order) was performed twice by two well-trained operators in optimal position. Using the same 3D MRA as a map and facilitated with the non-invasive optimal vessel analysis (NOVA) system, each scan was taken on a plane perpendicular to the target artery. Two consecutive full 13-artery scans were performed at least 15 min apart after participants were removed from the scanner table and then repositioned. A total of four PC flow images obtained from each target artery were transmitted to a workstation facilitated with the NOVA system. Flow data were calculated semi-automatically by the NOVA system after a few simple steps. Two-way mixed-effect models and standard errors of measurements were used. In 13 cerebral arteries, repeatability, using the intra-rater estimate expressed as the average-measures intraclass correlation coefficient, ranged from 0.641 to 0.954, and reproducibility, using the inter-rater estimate, ranged from 0.672 to 0.977. Except in the middle cerebral artery and the distal segment of the anterior cerebral artery, repeatability and reproducibility were excellent (intraclass correlation coefficient exceeded 0.8). The use of quantitative vessel-flow PC-MRI is a precise means to measure blood flow in most target cerebral arteries. This was evidenced by inter-rater and intra-rater correlations that were good/excellent, indicating good reproducibility and repeatability.This publication has 21 references indexed in Scilit:
- Assessing test–retest reliability of phase contrast MRI for measuring cerebrospinal fluid and cerebral blood flow dynamicsMagnetic Resonance in Medicine, 2019
- In Vivo Evaluation of Quantitative MR Angiography in a Canine Carotid Artery Stenosis ModelAmerican Journal of Neuroradiology, 2011
- Part 8: Adult Advanced Cardiovascular Life SupportCirculation, 2010
- Regional Cerebral Blood Flow Using Quantitative MR AngiographyAmerican Journal of Neuroradiology, 2007
- Use of Quantitative Magnetic Resonance Angiography To Stratify Stroke Risk in Symptomatic Vertebrobasilar DiseaseJournal of Vascular Surgery, 2005
- Improved phase-contrast flow quantification by three-dimensional vessel localizationMagnetic Resonance Imaging, 2000
- In Vivo Validation of MR Velocity ImagingJournal of Computer Assisted Tomography, 1987
- Blood Flow Imaging by Cine Magnetic ResonanceJournal of Computer Assisted Tomography, 1986
- Measurement of Flow with NMR Imaging Using a Gradient Pulse and Phase Difference TechniqueJournal of Computer Assisted Tomography, 1984
- A flow velocity zeugmatographic interlace for NMR imaging in humansMagnetic Resonance Imaging, 1982