Improved pre-operative diagnostic accuracy for low-grade prosthetic joint infections using second-generation multiplex Polymerase chain reaction on joint fluid aspirate
Open Access
- 15 April 2020
- journal article
- research article
- Published by Springer Science and Business Media LLC in International Orthopaedics
- Vol. 44 (9), 1629-1637
- https://doi.org/10.1007/s00264-020-04552-7
Abstract
Background A major obstacle for the treatment of prosthetic joint infection (PJI) is the identification of the underlying causative organism. While the diagnostic criteria ruling PJI in or out have become ever more accurate, the detection of the causative pathogen(s) still relies mostly on conventional and time-consuming microbial culture. The aim of this study was to evaluate the diagnostic potential of a second-generation multiplex PCR assay (Unyvero ITI G2, Curetis AG, Holzgerlingen, Germany) used on synovial fluid specimens. Our hypothesis was that the method would yield a higher diagnostic accuracy in the pre-operative workup than synovial fluid culture. Thus, a more precise classification of septic and aseptic prosthesis failure could be achieved before revision surgery. Methods Prospectively collected frozen joint fluid specimens from 26 patients undergoing arthroplasty revision surgery of the hip or knee were tested as per the manufacturer’s protocol. Sensitivities, specificities, positive and negative predictive values as well as positive and negative likelihood ratios with corresponding confidence intervals were estimated using the statistical software R. A combination of the serum C-reactive protein (CRP) level, leukocyte count, erythrocyte sedimentation rate, joint fluid culture, tissue biopsy culture, and tissue biopsy histology served as the gold standard. Results Of the 26 patients included in the study, 15 were infected and 11 were aseptic. Conventional joint fluid culture showed a sensitivity of 0.67 and a specificity of 0.91. Joint fluid multiplex PCR yielded a sensitivity of 0.8 and a specificity of 1.0. Conclusions Using the second-generation Unyvero ITI cartridge on joint fluid aspirate for the detection of prosthetic joint infection, we were able to achieve a higher diagnostic accuracy than with conventional culture. We conclude that to improve pathogen detection before revision surgery, this method represents a valuable and practicable tool.Keywords
Funding Information
- Deutsche Kniegesellschaft (8810002518)
This publication has 53 references indexed in Scilit:
- Two-stage Exchange Arthroplasty for Infected Total Knee Arthroplasty: Predictors of FailureClinical Orthopaedics and Related Research, 2011
- Definition of Periprosthetic Joint Infection: Is There a Consensus?Clinical Orthopaedics and Related Research, 2011
- New Definition for Periprosthetic Joint Infection: From the Workgroup of the Musculoskeletal Infection SocietyClinical Orthopaedics and Related Research, 2011
- New methods for the detection of orthopedic and other biofilm infectionsFEMS Immunology & Medical Microbiology, 2011
- The value of synovial biopsy, joint aspiration and C-reactive protein in the diagnosis of late peri-prosthetic infection of total knee replacementsThe Journal of Bone and Joint Surgery. British volume, 2008
- What is the significance of a positive Propionibacterium acnes culture around a joint replacement?International Orthopaedics, 2008
- Evaluation of Conventional Microbiological Procedures and Molecular Genetic Techniques for Diagnosis of Infections in Patients with Implanted Orthopedic DevicesJournal of Clinical Microbiology, 2008
- Sonication of Removed Hip and Knee Prostheses for Diagnosis of InfectionThe New England Journal of Medicine, 2007
- Proposal for a histopathological consensus classification of the periprosthetic interface membraneJournal of Clinical Pathology, 2006
- The Use of Confidence or Fiducial Limits Illustrated in the Case of the BinomialBiometrika, 1934