Wear Behavior Characterization of Hydrogels Constructs for Cartilage Tissue Replacement
Open Access
- 16 January 2021
- Vol. 14 (2), 428
- https://doi.org/10.3390/ma14020428
Abstract
This paper aims to characterize the wear behavior of hydrogel constructs designed for human articular cartilage replacement. To this purpose, poly (ethylene glycol) diacrylate (PEGDA) 10% w/v and gellan gum (GG) 1.5% w/v were used to reproduce the superior (SUP) cartilage layer and PEGDA 15% w/v and GG 1.5% w/v were used to reproduce the deep (DEEP) cartilage layer, with or without graphene oxide (GO). These materials (SUP and DEEP) were analyzed alone and in combination to mimic the zonal architecture of human articular cartilage. The developed constructs were tested using a four-station displacement control knee joint simulator under bovine calf serum. Roughness and micro-computer tomography (µ-CT) measurements evidenced that the hydrogels with 10% w/v of PEGDA showed a worse behavior both in terms of roughness increase and loss of uniformly distributed density than 15% w/v of PEGDA. The simultaneous presence of GO and 15% w/v PEGDA contributed to keeping the hydrogel construct’s characteristics. The Raman spectra of the control samples showed the presence of unreacted C=C bonds in all the hydrogels. The degree of crosslinking increased along the series SUP < DEEP + SUP < DEEP without GO. The Raman spectra of the tested hydrogels showed the loss of diacrylate groups in all the samples, due to the washout of unreacted PEGDA in bovine calf serum aqueous environment. The loss decreased along the series SUP > DEEP + SUP > DEEP, further confirming that the degree of photo-crosslinking of the starting materials plays a key role in determining their wear behavior. μ-CT and Raman spectroscopy proved to be suitable techniques to characterize the structure and composition of hydrogels.Keywords
Funding Information
- European Union's Horizon 2020 research and innovation program, project ADMAIORA (814413)
This publication has 43 references indexed in Scilit:
- Tissue mimicking materials for the detection of prostate cancer using shear wave elastography: A validation studyMedical Physics, 2013
- Hydrogels for biomedical applicationsAdvanced Drug Delivery Reviews, 2012
- Tailoring Properties of Biocompatible PEG-DMA Hydrogels with UV LightMaterials Sciences and Applications, 2012
- Mobile or fixed unicompartmental knee prostheses? In-vitro wear assessments to solve this dilemmaJournal of the Mechanical Behavior of Biomedical Materials, 2011
- Modified Gellan Gum hydrogels with tunable physical and mechanical propertiesBiomaterials, 2010
- Fabrication and characterization of poly(γ-glutamic acid)-graft-chondroitin sulfate/polycaprolactone porous scaffolds for cartilage tissue engineeringActa Biomaterialia, 2009
- Micro-CT 3D Image Analysis Techniques for Orthopedic Applications: Metal Implant-to-Bone Contact Surface and Porosity of BiomaterialsPublished by World Scientific Pub Co Pte Ltd ,2008
- Investigation on Wear of Knee Prostheses Under Fixed Kinematic ConditionsArtificial Organs, 2007
- Projections of Primary and Revision Hip and Knee Arthroplasty in the United States from 2005 to 2030The Journal of Bone & Joint Surgery, 2007
- Osteoarthritis: symptoms, signs and source of painInflammopharmacology, 2004