Optimization of hexagonal‐pattern minibeams for spatially fractionated radiotherapy using proton beam scanning
- 22 April 2020
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 47 (8), 3485-3495
- https://doi.org/10.1002/mp.14192
Abstract
Purpose In this study, we investigated computationally and experimentally a hexagonal‐pattern array of spatially‐fractionated proton minibeams produced by proton pencil beam scanning (PBS) technique. Spatial fractionation of dose delivery with millimeter or submillimeter beam size has proven to be a promising approach to significantly increase the normal tissue tolerance. Our goals are to obtain an optimized minibeam design and to show that it is feasible to implement the optimized minibeams at the existing proton clinics. Methods An optimized minibeam arrangement is one that would produce high peak‐to‐valley dose‐ratios (PVDRs) in normal tissues and a PVDR approaching unity at the Bragg peak. Using Monte Carlo (MC) code TOPAS we simulated proton pencil beams that mimic those available at the existing proton therapy facilities and obtained a hexagonal‐pattern array of minibeams by collimating the proton pencil beams through the 1‐3 mm diameter pinholes of a collimator. We optimized the minibeam design by considering different combinations of parameters including collimator material and thickness (t), center‐to‐center (c‐t‐c) distance, and beam size. The optimized minibeam design was then evaluated for normal tissue sparing against the uniform pencil beam scanning (PBS) by calculating the therapeutic advantage (TA) in terms of cell survival fraction. Verification measurements using radiochromic films were performed at the Emory proton therapy center (EPTC). Results Optimized hexagonal‐pattern minibeams having PVDRs of >10 at phantom surface and of >3 at depths up to 6 cm were achieved with 2 mm diameter modulated proton minibeams (with proton energies between 120 and 140 MeV) corresponding to a spread‐out‐Bragg‐peak (SOBP) over the depth of 10‐14 cm. The results of the film measurements agree with the MC results within 10%. The TA of the 2 mm minibeams against the uniform PBS is > 3 from phantom surface to the depth of 5 cm and then smoothly drops to ~1.5 as it approaches the proximal edge of the SOBP. For 2 mm minibeams and 6 mm c‐t‐c distance, we delivered 1.72 Gy at SOBP for 7.2 × 7.2 × 4 cm3 volume in 48 seconds. Conclusions We conclude that it is feasible to implement the optimized hexagonal‐pattern 2 mm proton minibeam radiotherapy at the existing proton clinics, because desirable PVDRs and TAs are achievable and the treatment time is reasonable.Keywords
This publication has 36 references indexed in Scilit:
- Spatially fractionated proton minibeamsThe British Journal of Radiology, 2019
- Microbeam radiation therapy — grid therapy and beyond: a clinical perspectiveThe British Journal of Radiology, 2017
- Optimization of beam arrangements in proton minibeam radiotherapy by cell survival simulationsMedical Physics, 2017
- Therapeutic advantage of grid irradiation for large single fractionsInternational Journal of Radiation Oncology*Biology*Physics, 2004
- Dose-volume effects in the rat cervical spinal cord after proton irradiationInternational Journal of Radiation Oncology*Biology*Physics, 2002
- Volume effects in radiobiology as applied to radiotherapyRadiotherapy and Oncology, 2000
- Volume effects in the irradiated canine spinal cord: do they exist when the probability of injury is low?Radiotherapy and Oncology, 1998
- Spatially fractionated (GRID) radiation for palliative treatment of advanced cancerRadiation Oncology Investigations, 1996
- The radiation response of the cervical spinal cord of the pig: Effects of changing the irradiated volumeInternational Journal of Radiation Oncology*Biology*Physics, 1995
- Tolerance of Mouse-Brain Tissue to High-Energy DeuteronsScience, 1959