A deep learning methodology for the automated detection of end-diastolic frames in intravascular ultrasound images
Open Access
- 15 February 2021
- journal article
- research article
- Published by Springer Science and Business Media LLC in The International Journal of Cardiovascular Imaging
- Vol. 37 (6), 1825-1837
- https://doi.org/10.1007/s10554-021-02162-x
Abstract
Coronary luminal dimensions change during the cardiac cycle. However, contemporary volumetric intravascular ultrasound (IVUS) analysis is performed in non-gated images as existing methods to acquire gated or to retrospectively gate IVUS images have failed to dominate in research. We developed a novel deep learning (DL)-methodology for end-diastolic frame detection in IVUS and compared its efficacy against expert analysts and a previously established methodology using electrocardiographic (ECG)-estimations as reference standard. Near-infrared spectroscopy-IVUS (NIRS-IVUS) data were prospectively acquired from 20 coronary arteries and co-registered with the concurrent ECG-signal to identify end-diastolic frames. A DL-methodology which takes advantage of changes in intensity of corresponding pixels in consecutive NIRS-IVUS frames and consists of a network model designed in a bidirectional gated-recurrent-unit (Bi-GRU) structure was trained to detect end-diastolic frames. The efficacy of the DL-methodology in identifying end-diastolic frames was compared with two expert analysts and a conventional image-based (CIB)-methodology that relies on detecting vessel movement to estimate phases of the cardiac cycle. A window of ± 100 ms from the ECG estimations was used to define accurate end-diastolic frames detection. The ECG-signal identified 3,167 end-diastolic frames. The mean difference between DL and ECG estimations was 3 ± 112 ms while the mean differences between the 1st-analyst and ECG, 2nd-analyst and ECG and CIB-methodology and ECG were 86 ± 192 ms, 78 ± 183 ms and 59 ± 207 ms, respectively. The DL-methodology was able to accurately detect 80.4%, while the two analysts and the CIB-methodology detected 39.0%, 43.4% and 42.8% of end-diastolic frames, respectively (P < 0.05). The DL-methodology can identify NIRS-IVUS end-diastolic frames accurately and should be preferred over expert analysts and CIB-methodologies, which have limited efficacy.Keywords
Funding Information
- British Heart Foundation (PG/17/18/32883)
- UCLH Biomedical Research Centre (BRC492B)
- Rosetrees Trust (A1773)
This publication has 33 references indexed in Scilit:
- Prediction of Progression of Coronary Artery Disease and Clinical Outcomes Using Vascular Profiling of Endothelial Shear Stress and Arterial Plaque CharacteristicsCirculation, 2012
- Clinical expert consensus document on standards for acquisition, measurement and reporting of intravascular ultrasound regression/progression studiesEuroIntervention, 2011
- Intravascular Ultrasound for the Evaluation of Therapies Targeting Coronary AtherosclerosisJournal of the American College of Cardiology, 2007
- Accuracy of Electrocardiographic-Gated Versus Nongated Volumetric Intravascular Ultrasound Measurements of Coronary Arterial NarrowingThe American Journal of Cardiology, 2007
- Detection of cardiac cycle from intracoronary ultrasoundJapanese Journal of Clinical Oncology, 2006
- Image-based cardiac gating for three-dimensional intravascular ultrasound imagingJapanese Journal of Clinical Oncology, 2005
- Retrospective image‐based gating of intracoronary ultrasound images for improved quantitative analysis: The intelligate methodCatheterization and Cardiovascular Interventions, 2003
- Cross-Validation MethodsJournal of Mathematical Psychology, 2000
- ECG-Gated Three-dimensional Intravascular UltrasoundCirculation, 1997
- Dynamic expansion of the coronary arteries: Implications for intravascular ultrasound measurementsAmerican Heart Journal, 1995