Abstract
The urgent task is to research in detail the possibilities of operation of the reverse osmosis membrane in the conditions of changing various parameters, which include, first of all, the working pressure, the initial concentration of the cleaning solutions, as well as the working conditions and the complete set of cleaning stands with auxiliary filters: mechanical, ceramic and carbon, which improves the quality of water and increases the life of high-value reverse osmosis modules. Particular attention was paid in this series of experiments to the role of ceramic filters, since in the previous series of experiments the concentration of the solution did not change both after mechanical and after carbon filters. Therefore, it was decided to modernize the stand and use a ceramic filter in the flow chart. In this work the detailed scheme of bench-scale setup with using of ceramic and carbon filters and also reverse-osmosis module is represented. The experimental reseaches of purification of NaCl water solutions were carried out in wide range of concentrations (0,2∙10-3…6,5 g/l) and working pressures (0,2…0,65 MPa). The comparative characteristics of main process parameters with and without ceramic filter are represented. The experiments were carried out on a laboratory stand for complex purification of aqueous solutions by microfiltration, adsorption and reverse osmosis using the following process steps carried out in the respective apparatus.